4

Heat transfer medium

Tyfocor non-toxic heating liquid for solar
heating systems with active anti-corrosion
and anti-ageing protection.
Frost protection:

to -31ºF / -35ºC

Specific gravity

at 68ºF / 20ºC:

1.032 to 1.035 g/cm

3

to ASTM D 1122

Viscosity
at 68ºF / 20ºC:

6.5 to 8.0 mm

2

/s

to DIN 51562

pH value:

7.5 to 8.5

to ASTM D 1287

Color:

transparent,
blue-green

Container:

5.3 USG / 20 ltr in a
disposable container

Standard equipment

Vitosol 100-F, Models SH1 and SV1 come
fully assembled in shrink-wrap packaging
and ready to be connected.

Accessories

Accessories (individually packed, depending
on order):
- Mounting hardware with technical

literature

- Interconnection pipes with insulation
- General connection set

- Sensor well set
- Solar Divicon (pumping station for the

collector circuit)

- Automatic air vent with air separator
- Fast air vent valve with tee and

shutoff valve

- System filling manifold

- Solar hand pump
- Solar expansion tank
- Heat transfer medium

Mounting hardware

The mounting hardware consists of

components required for the relevant
method of installation, such as:

Roof brackets, mounting plates, mounting
rails, connecting elements for mounting
rails, clamping bolts, screws and nuts.

General connection set

Required to connect solar collector to
system piping. One set required per collector
array - max. 269 ft

2

/ 25 m

2

.

Part No. 7248 240

Pipe connection set

Required to connect multiple solar
collectors.
Part No. 7248 239

x 2

Sloped roof hardware

Required for mounting collector directly onto
shingled roof. Raises collector 3½” /
889 mm above the roof.

Roof bracket

Installation rail

Flat roof hardware

Required for freestanding, flat roof
installations.

Solar Divicon

Preassembled pumping station for solar
collector circuit.
Includes: 3-speed pump (2 sizes), pressure
gage, 2 thermometers, 2 ball valves,
pressure relief valve, flow meter, 2
flowcheck valves, air separator, system fill
manifold, and foam insulation cover.
Part No. 7134 799 (for DN20)

7134 800 (for DN25)

Vitosolic 200

Electronic differential temperature control
for solar heating.
Part No. 7134 552

Main menu:

Actual values

Reports

Solar

Please note

Viessmann offers complete solar heating
system combi packages, as well as
comprehensive design support in order to

facilitate the component selection process.

5354

729

v1

.0

Pr

in

te

d

on

env

ironm

en

ta

lly

fr

ie

ndl

y

(r

ecy

cl

ed

an

d

re

cy

cl

ab

le

)

pap

er

.

Te

chni

ca

li

nfor

m

at

io

n

subj

ec

t

to

ch

ange

w

ithout

noti

ce

.

Summary of Contents for VITOSOL 100-F SV1

Page 1: ...ntal installation on sloped and flat roofs To produce domestic hot water or to supplement low temperature heating systems or swimming pools via a heat exchanger Technical Data Manual Part Nos and Pricing see Price List Meets the requirements of the German Blue Angel certificate of environmental excellence to RAL UZ 73 Certified in accordance with Solar Keymark testing requirements 5354 729 v1 0 03...

Page 2: ...f thermal radiation A meander shaped copper pipe through which the heat transfer medium flows is permanently embedded into the absorber The heat transfer medium channels the absorber heat through the copper pipe The absorber is encased in a highly insulated collector housing which minimizes collector heat losses The high quality thermal insulation provides temperature stability and is free from ga...

Page 3: ...n inches mm 22 22 Requirements for installation surface and anchorage Roof construction with adequate load capacity for prevailing wind forces 1 Important for system design considerations 2 Dimensions rounded to the nearest inch 3 Based on absorber surface area 4 In sealed systems operating pressure of at least 22 psig 0 45 psig x static head ft 1 5 bar 0 1 bar x static head m must be present in t...

Page 4: ... tank Heat transfer medium Mounting hardware The mounting hardware consists of components required for the relevant method of installation such as Roof brackets mounting plates mounting rails connecting elements for mounting rails clamping bolts screws and nuts General connection set Required to connect solar collector to system piping One set required per collector array max 269 ft2 25 m2 Part No...

Reviews: