Configuration of Vitotronic 200HO2B
Get access to Parameter level 2
1. Click on “Menu”
2. Click on “Service”
3. Enter password “viservice“ .
4. Click on “System configuration“
5. Click on “Parameter level 2”
6. Enter password “viexpert“
7. Choose “ Heating circuit X ”, the circuit you would like tado° to
control
8. Change the values according to the table on the right.
Use the “ arrows ” to change the settings and confirm with “OK” .
Parameter Beschreibung
Parameter
Value
Remote Detection
A0:
1
Room Temperature Hook-up
b0:
3
Room Influence Factor
b2:
20
Saving Function Room Temperature
b5:
5
If you want to control another heating circuit than heating
circuit 1 with tado° please contact our support and do not
start the configuration.
The passwords above are standard passwords which can be
changed. If the passwords does not work and you have not
changed them yourself please contact the heating engineer
that performed the installation of your boiler.
If parameter level 2 is not displayed, please contact our
customer support
You have now successfully completed the installation of your tado° Extension Kit. Please log back into your account and continue with the installation as displayed there.