Power supply for DHW circulation pump
DHW circulation pumps equipped with their own internal control unit
must be connected via a separate power supply. Connecting the
power supply via the heat generator control unit or its accessories is
not
permissible.
8.4 Condensate connection
Route the condensate drain pipe with a constant fall.
Route the condensate from the flue system together with the boiler
condensate directly or via a neutralising system (if installed – acces-
sories) to the public sewage system.
Note
A pipe vent
must
be installed between the trap and the neutralising
system.
Vitodens 200-W
A
B
A
Drain hose (Vitodens standard delivery)
B
Drain outlet kit (accessories)
Vitodens 222-W
A
B
A
Drain hose (Vitodens standard delivery)
B
Drain outlet kit (accessories)
Design information
(cont.)