Set-up
6
Tank Set-up
H
For narrow passageways, remove
upper and lower portion of crating and
carry DHW tank to its installation
location by means of crating boards
mounted on the tank.
H
Position tank carefully and remove
wood crating.
H
Locate tank(s) on flooring or
foundation capable of supporting the
weight of the tank(s) filled with
water.
H
The tank does not require a special
foundation and can be placed directly
on the floor. If, for cleanliness
purposes, the tank is to be kept off
the floor, a foundation for each tank
or tank battery can be used.
H
Level tank using leveling bolts on tank
frame.
Recommended installation clearances for service access
Storage capacity
USG
ltr
42
160
53
200
79
300
120
450
Rear
inches
mm
18
460
18
460
18
460
18
460
Sides
May be reduced if rear pipe
connections can be reached with
less clearance
inches
mm
12
300
12
300
12
300
12
300
Top
inches
mm
36
900
36
900
48
1200
48
1200
Front
inches
mm
24
600
24
600
24
600
24
600
Minimum clearances to combustibles
Storage capacity
USG
ltr
42
160
53
200
79
300
120
450
All sides
inches
mm
0
0
0
0
0
0
0
0
Floor
Combustibles
5
1
6
7
5
1
9
v
2
.2
Fig 1.
Leveling bolt
min. ¾” / 20 mm