198
Menu
■
"Device settings"
■
"Programming"
■
"Heating circ. 1"
,
"Heating circ. 2"
,
"Heating circuit 3"
■
"Room t hook-up slope"
Delivered condition
10
Setting
0 to 50
Room temperature hook-up (heating circuits)
This parameter determines the condi-
tions under which the set flow tempera-
ture with weather-compensated control
should be corrected by the room influ-
ence.
"0"
Weather-compensated control
without room influence. Set flow
temperature is not corrected.
"1"
Weather-compensated control
with room influence only for
"Reduced" operating mode.
"2"
Weather-compensated control
with room influence only for
"Standard" operating mode.
"3"
Weather-compensated control
with room influence for
"Reduced" and "Standard" oper-
ating modes.
Menu
■
"Device settings"
■
"Programming"
■
"Heating circ. 1"
,
"Heating circ. 2"
,
"Heating circuit 3"
■
"Room t hook-up"
Delivered condition
3
Setting
0 / 1 / 2 / 3
Maximum set flow temperature
Maximum permissible set flow temperature for a heating circuit.
Control settings, heating circuits
Influence of room temperature hook-up
(cont.)
5414 828 GB
Summary of Contents for VITOCAL 350-A
Page 54: ...54 5 3x 7 6 3x 3x 3x Installation sequence Fitting the outer panels cont 5414 828 GB ...
Page 58: ...58 2x 10 11 3x 3x Installation sequence Fitting the outer panels cont 5414 828 GB ...
Page 62: ...62 Type AWH I 1 Installation sequence Installing the heat pump cont 5414 828 GB ...
Page 228: ...228 052 054 059 008 056 025 020 Parts lists Parts list type AWH I cont 5414 828 GB ...
Page 236: ...236 053 032 039 034 038 033 034 039 027 Parts lists Parts list type AWH O cont 5414 828 GB ...
Page 237: ...237 052 054 059 008 055 025 020 Parts lists Parts list type AWH O cont 5414 828 GB Service ...