Viessmann VITOCAL 350-A Specifications Download Page 4

Vitocal 350-A

Heat pumps

2

3

4

5

1

2

Vitocal 350-A

1

  Inlet side

2

  Discharge side 

3

  Evaporator 

4

  Radial fan

5

   Hermetically sealed Compliant  

scroll compressor

Ideal for modernisation

With the Vitocal 350-A air/water heat pump, 
modernising is easy. The additional vapour 
injection in the compression process (EVI 
cycle) enables flow temperatures up to 65 °C. 
That makes it an ideal choice where older 
heating systems with radiators are installed. 
The heat pump draws its energy from the 
ambient air without needing to drill boreholes 
for geothermal probes.

High DHW convenience

Subject to model type, a higher flow 
temperature enables a water temperature of 
up to 55 °C inside the DHW cylinder. This allows 
the Vitocal 350-A to deliver a particularly high 
DHW convenience. The Vitocal 350-A 
achieves the high flow temperature of 65 °C 
even at outside temperatures of -10 °C.

RCD guarantees efficient operation

RCD stands for Refrigerant Cycle Diagnostic 
system. In the Vitocal 350-A, it is responsible 
for permanently monitoring the refrigerant 
circuit. This, in conjunction with the electronic 
expansion valve (EEV) ensures the highest 
efficiency at every operating point. Alongside 
this, important operating parameters are 
saved and called up, when required, for 
diagnosis, optimisation, energy statements 
and to calculate the seasonal efficiency.

Vitocal 350-A is tested 
in accordance with       
the EHPA heat pump 
quality seal.

Summary of Contents for VITOCAL 350-A

Page 1: ...VITOCAL 300 A VITOCAL 350 A Natural Heat Air source heat pumps ...

Page 2: ...nds and the conditions for installing a heat pump vary The range of accessories for the Vitocal 300 A is suitably flexible and comprehensive Subject to demand the heat pump can be supplied fully equipped This means the heating circuit pump expansion vessel and safety equipment have already been fully fitted Even the modular electric instantaneous heater can be easily integrated In conclusion Viess...

Page 3: ...rdance with EN 14511 3 5 air 2 C water 35 C 4 4 air 7 C water 35 C Maximum flow temperature up to 60 C Low operating noise through radial fan and reduced fan speed during night operation Efficient defrosting through circuit reversal Heat pump control unit for remote control and monitoring Particularly quiet outdoor silent version available 230 V single phase unit Easy to operate Vitotronic 200 hea...

Page 4: ...er flow temperature enables a water temperature of up to 55 C inside the DHW cylinder This allows the Vitocal 350 A to deliver a particularly high DHW convenience The Vitocal 350 A achieves the high flow temperature of 65 C even at outside temperatures of 10 C RCD guarantees efficient operation RCD stands for Refrigerant Cycle Diagnostic system In the Vitocal 350 A it is responsible for permanentl...

Page 5: ...nce with EN 14511 3 5 air 2 C water 35 C 4 1 air 7 C water 35 C High efficiency all year round at any operating point and therefore low consumption costs through innovative RCD Refrigerant Cycle Diagnostic system with an electronic bi flow expansion valve EEV Low operating noise through radial fan sound optimised design and night operation with reduced fan speed New heat pump control unit with tel...

Page 6: ...8 5 5 8 3 2 Overall dimensions Depth Width Height mm mm mm 946 880 1 870 946 1 030 1 870 946 1 200 1 870 1 265 1 380 1 885 1 265 1 530 1 885 1 265 1 700 1 885 Overall weight kg 287 297 361 325 335 400 External Internal Vitocal 300 A Type AWC I Vitocal 300 A Type AW O Länge Höhe Breite Height Width Depth Länge Höhe Breite Height Width Depth Vitocal 300 A Type AWC I AW O AW O Output data 100 EN 1451...