66
■ Clean interior
A
with a vacuum
cleaner first and then with a hand
shower. If necessary, wipe dry with a
soft cloth.
■ Check condensate drain
B
for free
drainage; flush if necessary.
■ Assembly: Steps 1 to 2 in reverse
order
Commissioning the system
Commissioning (configuration, parame-
ter settings and function check) can be
carried out with or without the commis-
sioning wizard (see following chapter
and service instructions for the heat
pump control unit).
Note
The type and extent of the parameters
depend on the appliance type, on the
selected system scheme and the acces-
sories employed.
Starting the heat pump
Switch ON the system power supply, e.g.
at the separate MCB/fuse or at a mains
isolator.
Commissioning with the commissioning wizard
The commissioning wizard automatically
guides you through all the menus where
settings have to be made. For this, "Cod-
ing level 1" is automatically active.
!
Please note
Incorrect operation at "Coding
level 1" may result in damage to
the appliance and the heating
system.
Observe the service instructions
for the "Vitotronic 200" heat pump
control unit, otherwise the appli-
ance warranty will be void.
Switch ON the ON/OFF switch on the
control unit.
■ The prompt
"Start commission-
ing?"
appears
automatically
on first
start-up.
Note
The commissioning wizard can also be
started manually:
To do this, press and hold
when
switching on the control unit (progress
bar visible).
Commissioning, inspection, maintenance
Further details regarding the individual steps
(cont.)
5516 436 GB