19
System size
150 l, 2 m
2
200 l, 2.3 m
2
300 l, 4 m
2
DIN registration no.
Applied for
Cylinder capacity
l
150
200
300
Operating pressure on the DHW side
bar
MPa
10
1
10
1
10
1
Drawable water volume
on a sunny day (insolation of 6.7 kWh/m
2
) with no
reheating
■
Draw-off temperature 40 °C (V40)
l
184
239
362
■
Draw-off temperature 45 °C (V40)
l
142
179
284
Thermal insulation
Rigid PUR foam
System dimensions
■
Height
a
mm
2575
2875
2575
■
Width
c
, overall width incl. connections
mm
1460
1785
2200
■
Depth
h
, incl. insulation
7
mm
550
550
685
■
Total weight, excl. mounting frame
kg
130
135
190
DHW cylinder dimensions
■
Width
b
mm
1410
1735
1680
■
Depth
e
7
mm
500
500
600
■
Weight
kg
70
90
110
Collector dimensions
■
Height
d
mm
2066
2380
2066
■
Collector width
f
mm
1056
1056
1056
■
Depth
g
mm
70
70
70
■
Weight
kg
40
45
40
Absorber area
m
2
2.01
2.32
4.02
Aperture area
m
2
2.02
2.33
4.03
Connections
■
DHW, side outlet tee
G
¾
G
¾
G
¾
■
Cold water
R
¾
R
¾
R
¾
Immersion heater, pre-fitted, 230 V/50 Hz
kW
3
3
3
Collector support angle, flat roof
45°
■
Depth
l
■
Height
k
mm
mm
1900
2125
2125
2345
1900
2220
30°
■
Depth
l
■
Height
k
mm
mm
2310
1705
2585
1835
2310
1795
15°
■
Depth
l
■
Height
k
mm
mm
2570
900
2870
1230
2570
1230
Space requirement on pitched roof
a
x
c
Specification
Specification
5786 170 GB
Appendix
Summary of Contents for TS1