15
Depending on the installation and set-
tings, your heating system is either
room temperature-dependent or
weather-compensated in conjunction
with an outside temperature sensor.
■ In
room temperature-dependent
mode
, the set room temperature is
controlled via the flow temperature.
■ In
weather-compensated mode
with room influence
, the set room
temperature is controlled via the
selected heating curve and room
influence factor. The room influence
factor can be set by your local heat-
ing contractor.
■ In
weather-compensated mode
without room influence
, the room
temperature is controlled via thermo-
static valves. At the temperature lev-
els Comfort 1 to 3 and Party, the flow
temperature is controlled according
to the selected heating curve. In
reduced mode (setback mode and
eco mode), the flow temperature is
reduced by a parallel shift of the
heating curve. The setting of the
heating curve and the height of the
parallel shift can be changed by your
heating contractor.
Note
In weather-compensated mode with-
out room influence, choosing temper-
ature levels Comfort 1 to 3 or Party
does not result in different room tem-
peratures.
Commissioning
Heating system operating mode
5837779