Danger
Escaping refrigerant can lead to explosions that
result in very serious injuries.
■
Always use
non-sparking
tools for all work.
■
Do not use any electrical tools, e.g. electric
drills or cordless screwdrivers.
Danger
Contact with live components can lead to seri-
ous injury from electric current. Some compo-
nents on PCBs remain live even after the power
supply has been switched off.
■
Never touch
wiring chambers.
■
When working on the appliance, isolate the
system from the power supply, e.g. at a sepa-
rate MCB/fuse or a mains isolator. Check that
it is no longer live. Safeguard against recon-
nection.
■
To avoid spark formation:
Prior to working on the appliance, wait at
least 4 min until the voltage has completely
dropped out.
3.
2.
1.
4.
Fig. 25
Electrical connections to the heat pump
Danger
Risk of explosion: Electrical components can
cause sparks, which may ignite escaping refrig-
erant.
After every opening and closing of the control
panel on the appliance door, check the gas tight-
ness to EN 60079-15: See chapter "Checking
the gas tightness of the control panel".
Maintenance
Removing the outer panels
5800 917 GB
Maintenance