113
Pump/component
Parameter
Setting
Circulation pump for
DHW reheating
"External heat source"
Ó
"Enable external heat
source 7B00"
"1"
"External heat source"
Ó
"Enable external heat
source for DHW heating
7B0D"
"1"
Solar thermal system
"Solar"
Ó
"Type solar control unit
7A00"
■
"1"
(with Vitosolic 100)
■
"2"
(with Vitosolic 200)
Remote control
(e.g. Vitotrol 200A)
"Heating circuit 1"
Ó
"Remote control 2003"
or
"Heating circuit 2"
Ó
"Remote control 3003"
or
"Heating circuit 3"
Ó
"Remote control 4003"
"1"
Note
Set code at the Vitotrol 200A
to assign heating circuits:
H1 for heating circuit A1
H2 for heating circuit M2
H3 for heating circuit M3
(see Vitotrol 200 A installa-
tion instructions)
Vitocom 100
"System definition"
Ó
"Vitocom 100 7017"
"1"
External extension H1
"System definition"
Ó
"External extension
7010"
"1"
Note
For parameters for external
functions, see separate
table.
Commissioning, inspection, maintenance
Further details regarding the individual steps
(cont.)
5600 161 GB
Service
Summary of Contents for BW 01.A06
Page 121: ...121 Opening the shield Troubleshooting Repairs cont 5600 161 GB Service ...
Page 166: ...166 5600 161 GB ...
Page 167: ...167 5600 161 GB ...