138
Type AWT-AC
221.A04
221.A07
221.A10
221.A13
Heating water
at 10 K spread
Capacity
l
16.7
16.7
17.7
17.7
Minimum flow rate
(always maintain)
l/h
600
820
1200
1380
Max. external pres-
sure drop (RFH) at
min. flow rate
mbar
kPa
590
59
540
54
440
44
380
38
Max. flow tempera-
ture
°C
55
55
55
55
External unit elec-
trical values
■ Rated voltage,
compressor
1/N/PE 230 V/50 Hz
■ Max. rated cur-
rent, compressor
A
13.5
15.7
19.6
26.5
■ Starting current,
compressor
A
10.5
15
10
10
■ Starting current,
compressor with
stalled armature
A
20
25
25
32
■ Starting current
(charging DC ca-
pacitors)
A
45
< 35
30
30
■ Fuse protection
A
20
20
20
32
■ IP rating
IP
24
24
24
24
Specification
Specification
(cont.)
5782 201 GB