136
230 V appliances
Type AWT-AC
221.A04
221.A07
221.A10
221.A13
Heating output
data
At 100 % according
to EN 14511
(A2/W35 °C,
spread 5 K)
Rated heating out-
put
kW
3.0
5.6
7.7
10.6
Compressor fre-
quency
Hz
60
65
55
75
Fan speed
rpm
870
650
650
650
Power consump-
tion
kW
0.91
1.73
2.20
3.25
Coefficient of per-
formance ε (COP)
in heating mode
3.30
3.24
3.50
3.26
Output control
kW
1.1 – 3.8
1.3 – 7.7
4.4 – 9.9
5.0 – 11.9
Heating output
data
At 100 % according
to EN 14511
(A7/W35 °C,
spread 5 K)
Rated heating out-
put
kW
4.5
8.39
10.9
14.6
Compressor fre-
quency
Hz
60
65
55
75
Fan speed
rpm
870
650
650
650
Air flow rate
m
3
/h
2090
3600
4210
4210
Power consump-
tion
kW
0.97
1.96
2.36
3.40
Coefficient of per-
formance ε (COP)
in heating mode
4.64
4.28
4.62
4.29
Specification
Specification
5782 201 GB