Installation and service instructions

for contractors

VIESMANN

Energy meter

3-phase

For applicability, see the last page

Energy meter

5678 581 GB

3/2017

Please keep safe.

Summary of Contents for 7769566

Page 1: ...Installation and service instructions for contractors VIESMANN Energy meter 3 phase For applicability see the last page Energy meter 5678 581 GB 3 2017 Please keep safe ...

Page 2: ...ally applicable standards a ÖNORM EN ÖVGW G K Guidelines ÖVGW TRF and ÖVE c SEV SUVA SVGW SVTI SWKI VKF and EKAS guideline 1942 LPG part 2 Safety instructions for working on the system Working on the system Where gas is used as the fuel close the main gas shut off valve and safeguard it against unintentional reopening Isolate the system from the power supply e g by removing the separate fuse or by...

Page 3: ...l isolator e g fuse box domestic distribution board Danger If water escapes from the appliance there is a risk of scalding Never touch hot heating water Condensate Danger Contact with condensate can be harmful to health Never let condensate touch your skin or eyes and do not swallow it Flue systems and combustion air Ensure that flue systems are clear and cannot be sealed for instance due to accum...

Page 4: ...e 7 Connecting the current sensors 8 Power supply 10 4 Commissioning Switching the power ON 12 Display elements 12 Instructing the system user 12 5 Troubleshooting Fault displays 13 Restoring the energy meter to its delivered condition 14 6 Parts lists Ordering parts 15 Parts list 16 7 Specification 18 8 Certificates Declaration of conformity 19 9 Keyword index 20 Index Index 5678 581 GB ...

Page 5: ...ur face Dispose of component correctly Dispose of component at a suitable collec tion point Do not dispose of component in domestic waste Product information The energy meter determines by means of 3 current sensors standard delivery whether there is an excess of on site generated power This information is passed on via the connection to the output control module In a continuously variable feed th...

Page 6: ...rid power supply utility and power exported to the grid power supply util ity P Terminal Q Current sensor R Control cable 1 Danger When subject to insolation PV modules can generate life threatening voltages Contact with live parts e g terminals can lead to burns and electric shock even if the PV modules are not connected First disconnect the inverter from the AC grid AC side of the inverter Then ...

Page 7: ...B Connecting cable max 10 m long C Energy meter Recommended connecting cables 3 x 0 5 mm2 max 10 m long Note Never route this lead immediately next to 230 400 V cables over long distances Output control module installation and service instructions Electrical connections Connecting the output control module 5678 581 GB Service ...

Page 8: ...or with 3 m connecting cable energy meter standard delivery D Energy meter Core assignment 1 Red 2 Black Connect current sensors in the correct position as shown in fig 3 Green point facing in the direction of the RCD Arrow of the K Ó L imprint on the inside of current sensor clip pointing in the direction of the RCD Electrical connections Connecting the current sensors 5678 581 GB Service ...

Page 9: ...with 3 m connecting cables energy meter standard delivery D Energy meter Core assignment 1 Red 2 Black 3 Red 4 Black 5 Red 6 Black Connect current sensors in the correct position as shown in fig 4 Green point facing in the direction of the RCD Arrow of the K Ó L imprint on the inside of current sensor clip pointing in the direction of the RCD Electrical connections Connecting the current sensors c...

Page 10: ...on we recommend installing an AC DC sen sitive RCD RCD class B for DC fault cur rents that can occur with energy efficient equipment Danger Incorrect core assignment can result in serious injury and damage to the appliance Never interchange cores L and N In a 1 phase power circuit S 1 2 3 4 5 6 7 8 9 101112 13 14151617181920212223242526 N L1 L2 L3 L1 N 230 V A B C D E N GND L Fig 5 A Output contro...

Page 11: ... A slow C Power cable for energy meter D Energy meter E Power cable for output control module Connect the power cable to the energy meter as shown in fig 5 and 6 Recommended power cable In a 1 phase power circuit 3 core with a cross sec tion of 2 5 mm2 In a 3 phase power circuit 5 core with a cross sec tion of 2 5 mm2 Electrical connections Power supply cont 5678 581 GB Service ...

Page 12: ... LED flashes once every 10 Wh OFF Immersion heater not connected See page 13 2 Green Flashes Indicating apparent power The LED flashes once every 10 Wh OFF Immersion heater not connected See page 13 No function Red Flashes During the initialisation process at the first start up LED flashes for 20 s Wait until initialisation process has been completed OFF Initialisation process has been completed s...

Page 13: ...gy meter and output control module is faulty Electrical connection of current sensors is faulty Check all electrical connections Check orientation of current sensors see page 8 Switch power supply OFF and ON again Immersion heater could not be switched on Electrical connection between output control module and immersion heater is faulty The set DHW temperature has been reached Check the electrical...

Page 14: ...ss ful A Fig 8 A Reset button 1 Remove the cover 2 Press reset key A The energy meter is restored to its delivered condi tion and runs through an initialisation process Troubleshooting Restoring the energy meter to its delivered condition 5678 581 GB Service ...

Page 15: ...15 The following details are required when ordering parts Serial no see type plate A Position number of the part from this parts list Parts lists Ordering parts 5678 581 GB Components ...

Page 16: ...16 0001 0002 0003 A Fig 9 A Type plate Parts lists Parts list 5678 581 GB Components ...

Page 17: ...17 Pos Part 0001 Current sensor 0002 Installation and service instructions 0003 Type plate Parts lists Parts list cont 5678 581 GB Components ...

Page 18: ...onsumption 1 8 W Standby power consumption 2 W Y connection for measuring voltage 400 V 20 3 phase and neutral conductor Measuring accuracy current Accuracy category 2 Dimensions 105 110 60 Specification Specification 5678 581 GB Service ...

Page 19: ...ing standards ETSI EN 301 489 1 EN 61 010 ETSI EN 301 489 17 EN 61 326 1 ETSI EN 300 328 This product is designated _ in accordance with the following Directives 2014 30 EC 2014 35 EC 2014 53 EC Allendorf 01 March 2017 Viessmann Werke GmbH Co KG Authorised signatory Manfred Sommer Certificates Declaration of conformity 5678 581 GB Service ...

Page 20: ...tion 6 L LED indicators 12 M Mounting rail 6 O Output control module 7 P Parts 15 Parts list 15 Power supply 10 Product information 5 S Switching the power ON 12 Applicability Serial No 7769566 Viessmann Limited Hortonwood 30 Telford Shropshire TF1 7YP GB Telephone 44 1952 675000 Fax 44 1952 675040 E mail info uk viessmann com Viessmann Werke GmbH Co KG D 35107 Allendorf Telephone 49 6452 70 0 Fax...