background image

3

!

Please note

Electronic assemblies can be
damaged by electrostatic dis-
charge.
Prior to commencing any work,
touch earthed objects such as
heating or water pipes to dis-
charge static loads.

For opening the control units
and position 

A

 in the following

diagrams, see the correspond-
ing installation and service
instructions.

Vitotronic 100, 200, 300, 300-K, 333, 050, 200-H

■ Vitotronic 100, type GC1, GC1B,

GC4, GC4B, GC7B

■ Vitotronic 200, type GW1, GW1B,

GW4B

■ Vitotronic 050 and 200-H, type

HK1W, HK3W

■ Vitotronic 300, type GW2, GW2B,

GW4, GW4B

■ Vitotronic 300-K, type MW2, MW2B
■ Vitotronic 333, type MW2

B

A

A

Main control unit PCB

B

LON communication module

Vitotronic 100, 200, 300, type C...

■ Vitotronic 100, type CC1E
■ Vitotronic 200, type CO1E
■ Vitotronic 300, type CM1E

 

Installation

5780 510 GB

 

Summary of Contents for 7172173

Page 1: ...ation initial start up inspection maintenance and repairs must only be carried out by a competent person heating engineer installation contrac tor Before working on the equipment heat ing system isola...

Page 2: ...g applian ces in a heat pump cas cade with the following weather compensated control units WPR 300 Vitotronic 200 type WO1A WO1B WO1C Cascade control unit in multi boiler systems Vitotronic 300 K type...

Page 3: ...ng installation and service instructions Vitotronic 100 200 300 300 K 333 050 200 H Vitotronic 100 type GC1 GC1B GC4 GC4B GC7B Vitotronic 200 type GW1 GW1B GW4B Vitotronic 050 and 200 H type HK1W HK3W...

Page 4: ...Main control unit PCB B LON communication module Vitotronic 100 type CC1I Vitotronic 200 type CO1I Vitotronic 300 type CM1I B A A Main control unit PCB B LON communication module Installation cont 578...

Page 5: ...200 type KO1B KO2B A B Type KO1B is shown A Main control unit PCB B LON communication module Vitotronic 050 and 200 H type HK1M B A A Main control unit PCB B LON communication module Installation cont...

Page 6: ...6 Heat pump control units Vitotronic 200 type WO1 A B A Controller and sensor PCB B LON communication module Installation cont 5780 510 GB...

Page 7: ...7 WPR300 A X24 B A Sensor PCB B LON communication module Installation cont 5780 510 GB...

Page 8: ...8 Vitotronic 200 type HO2B HO1 B A A Main PCB B LON communication module Installation cont 5780 510 GB...

Page 9: ...9 Vitotronic 200 type KW6 B A A Main PCB B LON communication module Installation cont 5780 510 GB...

Page 10: ...nly use the specified cable types Use only one cable type within each LON Cable types on site 2 core cable CAT5 screened JY St Y 2 x 2 x 0 8 mm telephone cable Observe the requirements for cabling and...

Page 11: ...D D B B B C Installation spacing 7 to 21 m A Control unit or communication product B LON cable 7 m long Max 3 cables between 2 devices C Terminator D LON coupling Connection with on site cable and LON...

Page 12: ...0 subscribers Commissioning and adjustment Service and installation instruc tions and service instructions for the relevant appliance Viessmann Limited Hortonwood 30 Telford Shropshire TF1 7YP GB Tele...