background image

3

GB

1. Introduction

All products (5040, 5840 and 5539) can be pow-
ered with a commercially available transformer 
for model trains with a secondary voltage of 
14 – 16 V AC or DC. The warning boards supplied 
with articles 5040 and 5840 may only be con-
nected to the appropriate outputs of the electronic 
module 5539.
The power supply unit must be short circuit pro-
tected. When using DC please observe the cor-
rect polarity. If there is no effect when using DC, 
change the polarity at the transformer terminals.

These modules are designed for installation 
in a model train layout or a diorama.
Any wiring must be carried out while power 
is disconnected.
Please use an appropriate power supply as 
required. Only use devices that are certified 
by VDE- / CE and bear the appropriate 
marks.

2. Testing functionality

All 

Viessmann

 products undergo a stringent qual-

ity tests prior to packing including a function test. 
Since damage during transit cannot always be 
prevented you should carry out a test of the func-
tions prior to installation. 

Articles 5040 and 5840:

 Wire the electronic 

module and the warning boards as per fig. 1 for 
testing. Make sure polarity is correct. 

Article 5539:

 Wire the module as per Fig. 1 and 

observe correct polarity.

3. Mounting

The electronic module can be fastened with two 
wood screws on or under the layout (through the 
two large holes).
For mounting the warning boards (5040 and 5840) 
drill a 2.5 mm diameter hole in the baseboard. 
Then simply insert the boards. Fix them with some 
glue if necessary.

4. Wiring

Articles 5040 and 5840:

 Connect the warning 

boards as per fig. 1. 
Do not remove the resistors soldered to the wires 
of the warning boards! Otherwise the LEDs will be 
destroyed!

Article: 5539:

 Wiring is done as indicated in fig. 1. 

Instead of the warning boards you connect 12-14V 

Technical Data

Supply Voltage: 

10 – 16 Volt AC

Current consumption
(without bulbs resp. LEDs): 

appr. 20 mA

Outputs 1 – 8:

  Max. current loading 

100 mA

incandescent lamps or LEDs with the appropri-
ate resistors to the 8 outputs (see insert in fig. 1). 

Viessmann

 offers the necessary components in its 

vast product range:

Incandescent lamps: 3500 (blue), 3501 (yellow), 
3502 (red), 3503 (clear),

LED sets with resistors:
Ø 3 mm: 3350 (red), 3551 (yellow), 3552 (green) 
Ø 1.8 mm: 3353 (red), 3555 (yellow), 3554 (green)

5. Speed of Movement

 You may adjust the speed of the running lights by 
means of a small screw driver (as per Fig. 2).

6. Setting Functions

The 

Viessmann

 electronic module for running 

lights has two different functions:

Function A

 (basic function): the outputs are 

switched in series (one after the other) and are 
switched off simultaneously.

Function B:

 The outputs are individually switched 

one after the other, in other words only one light 
will be on at any one time. 
For setting Function B bridge the terminals 
marked B with a piece of wire.