8. Reasons of faults and ways to fix them
Fault
Smoke enters the
room when heating
Reason
Way to fix
Insufficient chimney draught
Install a chimney of suitable
Height of the chimney is insufficient
height and diameter
Diameter of the chimney is too small
Humidity of firewood is too high
Use firewood which humidity is up
Supply of air into the room is too low
to 20%
Make sure enough air is supplied
Fire dies in the
into the room, for example, install
a ventilation hole; switch the
fireplace
extractor fan off.
Air supply valve is closed
Open the air supply valve
Flue pipe is blocked with smut
Clean the flue
Too much ash in the bin
Remove the ash
Humidity of firewood is too high
Use firewood which humidity is up
to 20%
Unusually high
Large, whole firewood is used
Use cut firewood of the indicated
amount of smut on
size
the glass
Inappropriate fuel is used (e.g. rubber,
Use only the recommended fuel
plastic, wood waste etc.)
Open the secondary air supply
Secondary air supply valve is closed
valve
Wrong orientation of the firewood
Place the firewood in the firebox in
parallel with the glass.
Fireplace
Inappropriate fuel is used (e.g. coal)
Use the recommended type and
Too much fuel is loaded and the air supply
overheats
amount of fuel.
valve is open
Extremely dry wood (e.g. old furniture)
Fire in the chimney
The chimney is clogged with smut and has
Close air supply valve, close
not been cleaned for a long time
smoke damper, and call
firefighters
Carefully tighten the glass
Door glass is loose
Glass tightening bolts are loose
tightening bolts with the help of
screwdriver, be careful not to
tighten the bolts too much
because the glass may crack.
9. Transportation and storage
You may only transport fireplaces in a vertical position with any type of vehicle. When
transporting the fireplace it is necessary to protect it from rain or snow. In order to prevent
fireplaces from falling or scratching to each other during the transportation it is necessary to
fasten them securely in the vehicle. It is necessary to carefully perform loading and unloading
work and be careful not to break the fireplaces.
The fireplaces should be stored in a dry place. It is prohibited to store them together with
chemicals that react with metal.
When storing or transporting the fireplaces it is prohibited to store them one on top of
another. The fireplaces shall be transported and stored in the original package of the
manufacturer fastened to a wooden pallet and covered with polyethylene membrane if it is not
stipulated otherwise in the supply contract.