background image

 

Summary of Contents for EKO ex

Page 1: ...Instructions for installation and use Fireplace Stove Vienybė EKO ex ГОСТ 9817 95 Vienybė EKO ex 17 01 EN ...

Page 2: ......

Page 3: ...ion 6 4 Installation 7 4 1 Place of installation 7 4 2 Requirements for flue and chimney 8 Date of manufacture 5 Use 8 5 1 First heating 9 5 2 Heating 9 5 3 Ash cleaning 9 5 4 Fuel 9 6 Technical safety requirements 10 7 Maintenance 10 7 1 Glass cleaning 10 7 2 Interior and exterior cleaning 10 7 3 Replacement parts 10 8 Troubleshooting 11 9 Delivery and Storage 11 10 Package Contents 12 11 Warrant...

Page 4: ...s manual Taking into consideration the foregoing I have a claim in respect of this product I believe that defects listed in the claim occurred due to imperfection of your product and hereby ask you to send your representatives in order to inspect the connected product to identify the defects and to rectify them Should there be determined that the abovementioned defects were caused by improper conn...

Page 5: ...n acts of God the warranty does not apply to door glass and vermiculite plates I have read and understand the warranty terms and conditions 2 Technical specifications Name Units Value Fuel used Firewood Maximum recommended measurements of firewood mm Ø90 x 250 Efficiency at nominal power 71 5 Nominal thermal power when heating with firewood kW 8 Diameter of flue connection mm Ø130 Connection of fl...

Page 6: ...ir supply is sufficient e g install an air vent turn off cooker hood Open air supply valve Clean the flue Remove ashes Unusually high amount of soot on the glass Firewood is too damp Large non split firewood is being used Wrong type of fuel is being used e g rubber plastic wood waste etc Wrong orientation of firewood Use firewood with up to 20 humidity Use split firewood of recommended size Use on...

Page 7: ...TTENTION Use only original or recommended by the manufacturer replacement parts Use of non original replacement parts for repairs during the warranty period will void the warranty 4 Installation The fireplace shall be installed in premises that meet construction standards and requirements Installation and connection of the fireplace to a chimney shall be performed in accordance with Rules for inst...

Page 8: ...y valve by pulling it towards yourself Put two average size pieces of firewood on the bottom of a combustion chamber leave a gap between those two pieces Put some crumpled newspaper or a solid fuel tablet in the gap then put some shredded and dry firewood in a crosswise manner and then some average size firewood on top Light up the paper and close the door when the paper starts to burn well A hand...