for WC flush plates for PrevistaModel
Year built:
8522.31
from 01/2019
en_INT
Prevista Dry WC element height-adjustable
after installation by the installer
Instructions for Use
Page 1: ...for WC flush plates for Prevista Model Year built 8522 31 from 01 2019 en_INT Prevista Dry WC element height adjustable after installation by the installer Instructions for Use...
Page 2: ...Prevista Dry WC element height adjustable after installation by the installer 2 from 29...
Page 3: ...ical data 8 2 4 Accessories 9 3 Handling 10 3 1 Assembly information 10 3 1 1 Mounting conditions 10 3 1 2 Installation dimensions 11 3 2 Assembly 11 3 2 1 Mounting WC element 11 3 2 2 Connecting conc...
Page 4: ...sible operating instructions The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use 1 2 Labelling of notes Warning an...
Page 5: ...me passages in the text may refer to technical codes in Europe Germany These should serve as recommendations in the absence of corresponding national regulations The relevant national laws stand ards...
Page 6: ...ntended use 2 2 1 Areas of use The Prevista Dry WC element is suitable for mounting on masonry wall constructions and support profiles pursuant to the regulations in section Regulations from section F...
Page 7: ...l 10 Hard foam block 11 Corner valve 12 Revision shaft cover 2 3 2 Compatible components The WC element is compatible with all common WC ceramics even with larger projection barrier free The WC elemen...
Page 8: ...ection is required to extend the WC element to the shower WC Power must be connected on site 2 3 3 Technical data Small flush volume Factory setting approx 3 l Setting range approx 2 4 l Large flush v...
Page 9: ...o the installation body or corner mounting on masonry or metal support profile Prevista Dry fixing set model 8573 for single mounting of Prevista Dry elements to the solid wall Prevista Dry Plus fixin...
Page 10: ...ght the marked height of the upper edge of the finished floor must be observed The WC element has an R inch water connection The WC element can be extended by a remote flush actuation or by an electro...
Page 11: ...hen mounting multiple WC elements with an interval of 500 mm Viega recommends using a Prevista Dry support bracket model 8570 48 Observe the instructions for use of the support bracket when mounting M...
Page 12: ...nd mark the fixing points on the floor n X3 375 mm Drill the holes Insert the dowels INFO Mount the Prevista Dry fixing set pursuant to the instruc tions for use for the fixing set Loosen the feet of...
Page 13: ...th the on site marking of the upper edge of the finished floor n X 1000 mm Tighten the feet of the element using a fork spanner The element is attached to the wall Handling Prevista Dry WC element hei...
Page 14: ...on the element on the floor rail Fix the feet on the floor rail using the clips Set the height of the element by means of the feet Fix the element with the Prevista Dry Plus Steptec rail connectors Mo...
Page 15: ...The element is fixed in the Prevista Dry Plus pre wall construc tion Handling Prevista Dry WC element height adjustable after installation by the installer 15 from 29...
Page 16: ...the support profile Adjust the construction height of the element in accordance with the on site marking of the upper edge of the finished floor n X 1000 mm Attach the element to the support profiles...
Page 17: ...file Install the site protection of the flush actuation Push the hard foam block over the threaded rods onto the drain pipe Mounting the site protection of the flush actuation Handling Prevista Dry WC...
Page 18: ...e cover plate Place the press connector on the water inlet Press the connection Seal the threaded connectors of the corner valve Screw the corner valve into the thread side of the Steptec rail con nec...
Page 19: ...ern INFO Ensure the corner valve is correctly seated Use the lock nut to screw the corner valve and the cistern to one another Remove the protective cap from the water supply hose Screw the water supp...
Page 20: ...r plate lock by 90 in a clockwise direction Place the revision shaft on the cover plate To remove the revision shaft press in the fixing clips at the side Handling Prevista Dry WC element height adjus...
Page 21: ...ertically through the bare concrete floor is only possible with the drain elbow model 8095 Art No 713744 The screed height must be at least 85 mm 3 2 4 Set and clad the WC element Mark the contour of...
Page 22: ...e element with suitable gypsum cardboard cladding panels Re position the hard foam block Tile the WC element Handling Prevista Dry WC element height adjustable after installation by the installer 22 f...
Page 23: ...cessible n The water supply has been shut off n The ceramic has been mounted Fold the tabs forward Lift the drain valve Remove the drain valve through the revision opening Handling Prevista Dry WC ele...
Page 24: ...Set the large flush volume at the drain valve Set the small flush volume at the drain valve Handling Prevista Dry WC element height adjustable after installation by the installer 24 from 29...
Page 25: ...nlock the flushing throttle Set the flush flow at the throttle Lock the flushing throttle 3 2 6 Mounting WC ceramic Mark the insertion depth of the flush pipe and drainpipe Setting the flush flow Hand...
Page 26: ...Cut the flush pipe and drainpipe to length Deburr the flush pipe and drainpipe Handling Prevista Dry WC element height adjustable after installation by the installer 26 from 29...
Page 27: ...ush pipe and drainpipe with silicon grease and insert them Mount the WC ceramic Align and secure the WC ceramic 9 Handling Prevista Dry WC element height adjustable after installation by the installer...
Page 28: ...amic If not use cover plate model 8040 21 3 3 Use Loosen do not remove the fixing screws with fork spanner Adjust the WC ceramic s height Adjusting WC height Handling Prevista Dry WC element height ad...
Page 29: ...centration of calcium or magnesium salts there is the risk of limescale deposits developing on the inlet and drain valves The valves may have to be replaced depending on the extent of the deposits 3 5...