Viega 8161.20 Instructions For Use Manual Download Page 18

Unscrew the threaded rod of the WC fastening so that it projects out

by approx. 45 mm.

Attach the template (polystyrene) to the element.

Double clad the pre-wall element (2 x 12.5 mm).
Clad up to the template.
Lay tiles up to the template.

45 mm

0

Handling

Viega Eco Plus
Universal shower WC element

18 from  22

Summary of Contents for 8161.20

Page 1: ...for wall hung WCs wall hung shower WCs wall hung WCs with shower WC top Model Year built 8161 20 from 08 2015 en_INT Viega Eco Plus Universal shower WC element Instructions for Use...

Page 2: ...Viega Eco Plus Universal shower WC element 2 from 22...

Page 3: ...nts 8 2 4 3 Sound protection 11 2 4 4 Technical data 11 2 5 Accessories 11 3 Handling 12 3 1 Assembly information 12 3 1 1 Mounting conditions 12 3 1 2 Installation dimensions 13 3 1 3 Required tools...

Page 4: ...oduct This restriction does not extend to possible operating instructions The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructi...

Page 5: ...EN and or in Germany e g DIN DVGW Some passages in the text may refer to technical codes in Europe Germany These should serve as recommendations in the absence of corresponding national regulations T...

Page 6: ...iles DIN 18183 Regulations from section Sound protection Scope Notice Regulations applicable in Ger many Fulfilled noise protection require ments DIN 4109 Fulfilled noise protection require ments DIN...

Page 7: ...ct description 2 4 1 Overview The shower WC element is equipped as follows 1 2 3 4 5 6 7 8 9 10 1 Viega Eco Plus universal shower WC element 2 mounting template 3 threaded rods for wall mounted WC gau...

Page 8: ...Style 13 8333 1 Flush plate Visign for Style 14 8334 1 Functional unit 8332 3 Visign for More Flush plate Visign for More 100 8352 1 Flush plate Visign for More 101 8351 1 Flush plate Visign for More...

Page 9: ...plate Visign for Public 6 8326 15 Remote actuation Visign for Public 1 8326 21 Cover plate Visign for Public 8326 9 The Viega Eco Plus shower WC element 8161 20 is suitable for mounting with the foll...

Page 10: ...panel n Flexible hose R with union nut Rp n Ball valve R suitable for n Geberit AquaClean 4000 5000 5000 plus WC top n Duravit SensoWash E shower WC top n Villeroy Boch VICLEAN shower WC top Equipment...

Page 11: ...data Small flush volume Factory setting approx 3 l Setting range approx 3 4 l Large flush volume Factory setting approx ca 6 l Setting range approx 6 9 l Immediate re flushing is possible at the facto...

Page 12: ...on with wall hung WCs fixing gauges for bore hole 180 mm The shower WC element requires an on site 230 V mains connection The shower WC element requires an on site inch water connection The shower WC...

Page 13: ...l with 10 mm drill bit n ratchet with sockets 13 mm 17 mm n fork or ring spanner 13 mm 17 mm 19 mm n Phillips tip screwdriver n flat blade screwdriver n cordless screw driver n silicone press 3 2 Asse...

Page 14: ...ment and set the distance to the wall size 17 Determine mounting height in accordance with the on site marking of the upper edge of the finished floor INFO Any errors made at this stage of the assembl...

Page 15: ...nect water DANGER Danger due to electrical current An electric shock can lead to burns and serious injury and even death Work on the electrics may only be carried out by trained elec tricians Switch o...

Page 16: ...e side Reattach the template Determine the fixing points If necessary adjust feet from 50 mm to 75 mm Align the shower WC element using a spirit level Determine mounting height in accordance with the...

Page 17: ...s described in Mounting in masonry wall Create water and power connection on site 3 2 2 Set up element for wall covering using the template Determine threaded rod height for sanitary object SW 19 4x 4...

Page 18: ...at it projects out by approx 45 mm Attach the template polystyrene to the element Double clad the pre wall element 2 x 12 5 mm Clad up to the template Lay tiles up to the template 45 mm 0 Handling Vie...

Page 19: ...proceed as follows Loosen the four threaded nuts on the element SW 17 Loosen the four front threaded nuts on the sides of the H beam SW 17 Align all four points flush with the finished wall surface by...

Page 20: ...he fixing of the WC element to the required size and counter with threaded nuts SW 19 3 2 4 Setting the flush volume Immediate re flushing of the flush volume is possible at the factory settings The s...

Page 21: ...large flush volume n left approx 6 l n right approx 9 l 3 3 Cleaning and maintenance In consideration of the mechanical chemical and physical conditions the concealed cistern is constantly laden For t...

Page 22: ...rate the product and packaging materials e g paper metal plastic or non ferrous metals and dispose of in accordance with valid national legal requirements Handling Viega Eco Plus Universal shower WC e...

Reviews: