background image

¾

90

Ø 60

¾

35

100

17

60-130

Fig. 4: Dimensional drawing pipe interrupter

3.1.3

Required tools and materials

The following tools are required for mounting:

n

fine-toothed saw

n

water pump pliers

The following material must be available during mounting:

n

concealed pipe interrupter DN20

n

mounting material

n

rosette

3.2

Assembly

3.2.1

Mounting the pipe interrupter

Tool

Material

Preparations

Handling

Connection fitting concealed pipe interrupter

11 from  18

Summary of Contents for 6161.86

Page 1: ...Model Year built 6161 86 from 02 1998 en_INT Connection fitting concealed pipe inter rupter Instructions for Use ...

Page 2: ...Connection fitting concealed pipe interrupter 2 from 18 ...

Page 3: ...erview 7 2 3 2 Drinking water connection 7 2 3 3 Technical data 8 2 4 Required accessories 8 3 Handling 10 3 1 Assembly information 10 3 1 1 Mounting conditions 10 3 1 2 Installation dimensions 10 3 1 3 Required tools and materials 11 3 2 Assembly 11 3 2 1 Mounting the pipe interrupter 11 3 2 2 Connecting the tub inlet 15 3 2 3 Leakage test 15 3 3 Cleaning and maintenance 16 3 4 Disposal 18 Table ...

Page 4: ...e installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use 1 2 Labelling of notes Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs DANGER This symbol warns against possible life threatening injury WARNING This symbol warns against possible serious injur...

Page 5: ...y e g DIN DVGW Some passages in the text may refer to technical codes in Europe Germany These should serve as recommendations in the absence of corresponding national regulations The relevant national laws stand ards regulations directives and other technical provisions take priority over the German European directives specified in this manual The information herein is not binding for other countr...

Page 6: ...h the instructions in section Ä Chapter 2 3 2 Drinking water connec tion on page 7 the concealed pipe interrupter meets the require ments defined in the standards EN 1717 2 2 Intended use 2 2 1 Areas of use The concealed pipe interrupter connection fitting model 6161 86 is suit able for Multiplex drain overflows and for Rotaplex Trio drain overflows A corresponding rosette Visign RU1 model 6161 80...

Page 7: ... Pipelines are not allowed to rise downstream from the pipe interrupter n The pipe interrupter must be installed at least 150 mm above the highest possible non drinking water level n There must not be any shut off downstream from the pipe inter rupter n The pipe interrupter must not be involved in the pressure test with an installed membrane the membrane is destroyed during a pressure test and the...

Page 8: ... 15 0 2 0 25 0 3 0 35 0 4 0 45 1 2 Fig 2 Flowthrough diagram 1 Flowthrough litres per minute 2 Flow pressure Δp MPa 2 4 Required accessories A rosette must be purchased separately and a top stem must be fitted to complete the mounting of the pipe interrupter The rosette Visign RU1 model 6161 80 is suitable for the top stem of the concealed pipe interrupter Rosette Product information Connection fi...

Page 9: ...red the insert with the membrane must be exchanged for the connecting piece shown here model 6161 83 Two screws are required for the fixing of the concealed pipe interrupter Accessories for a pressure test Mounting material and connection screw fittings Product information Connection fitting concealed pipe interrupter 9 from 18 ...

Page 10: ...n The pipe and line in which the pipe interrupter is installed are suit able for the supply of drinking water n The tub fitting has been installed and the connection lines are acces sible 3 1 2 Installation dimensions 1500 1500 Fig 3 Dimensional drawing pipe connections Handling Connection fitting concealed pipe interrupter 10 from 18 ...

Page 11: ...re required for mounting n fine toothed saw n water pump pliers The following material must be available during mounting n concealed pipe interrupter DN20 n mounting material n rosette 3 2 Assembly 3 2 1 Mounting the pipe interrupter Tool Material Preparations Handling Connection fitting concealed pipe interrupter 11 from 18 ...

Page 12: ...nstream from the pipe interrupter Make sure that you have the required accessories rosette connec tion sets to be able to carry out the mounting work completely Make sure that during assembly the protective plug is to be found on the top stem Depending on the type of mounting the connection of the mixing tap and the pipe interrupter can made with pipes and a press connection or with plastic pipes ...

Page 13: ...the water bearing pipe Push the narrow end of the screw fitting into the pipe as far as it will go Push the free end of the screw fitting into the connection of the pipe interrupter Screw the connection together Euro cone connections are not compatible Adjust pipe interrupter Mark drill holes Drill holes Mounting Connecting and tiling 90 Handling Connection fitting concealed pipe interrupter 13 fr...

Page 14: ...ll If the shaft top is too long Shorten shaft top with a fine toothed saw Take care to shorten to the proper length The shaft top must be flush with the height of the tiles If impurities have managed to enter the shaft top during the work clean shaft top Shortening the shaft top Handling Connection fitting concealed pipe interrupter 14 from 18 ...

Page 15: ...fitting into the pipe as far as it will go Push the free end of the screw fitting into the connection elbow Screw in the pipe tight with the union nut onto the connection elbow Euro cone connections are not compatible Insert the connection elbow into the overflow unit The connection elbow must click into place in the overflow unit with a noticeable clicking sound 3 2 3 Leakage test The leakage tes...

Page 16: ...drinking water can contami nate drinking water To ensure the constant functionality of the pipe interrupter Have limescale deposits removed by trade professio nals as described in this chapter In the case of extensive limescale deposits have insert and membrane replaced by trade professionals as described in this chapter Remove rosette Grip and pull the insert out of the casing using multigrip pli...

Page 17: ...2 Hold the cleaned or new insert with multigrip pliers and insert into the casing of the pipe interrupter from the front Large amount of limescale and contamination Installation after cleaning Handling Connection fitting concealed pipe interrupter 17 from 18 ...

Page 18: ...or disinfectants containing the fol lowing ingredients may not be used n alcohol n ammoniac n hydrochloric acid n phosphoric acid n acetic acid 3 4 Disposal Separate the product and packaging materials e g paper metal plastic or non ferrous metals and dispose of in accordance with valid national legal requirements Cleaning the rosette Handling Connection fitting concealed pipe interrupter 18 from ...