3.2
Assembly
3.2.1
Connect and mount pipe interrupter
The pipe interrupter must be mounted according to the plan in
Chapter 3.1.1 „Mounting conditions“ on page 9 for the subsequent
installation of the bathtub before the work on the walls is finished. Pro-
ceed as follows:
n
The direction of flow runs from diagonal to vertical downwards.
n
The line does not continue to rise downstream from the pipe inter-
rupter.
n
All of the accessories (pipes, connecting pieces ¾ inch) required for
complete assembly are included.
n
During assembly, the protective plug is to be found on the top stem.
INFO! We show the mounting here with the Viega plug connec-
tion. Mounting can also be carried out with other connecting
materials. If necessary, observe the manufacturer's instructions.
Push the union nut and clamping ring onto the pipe.
Push Viega plug-in seat as far as it will go into the pipe.
Euro cone connections are not compatible.
Push the free end of the plug-in seat into the connection of the pipe
interrupter.
Using the union nut, screw the pipe tightly onto the pipe interrupter.
Repeat the procedure with the second pipe.
INFO! We show the mounting here with the Viega plug connec-
tion. Mounting can also be carried out with other connecting
materials. If necessary, observe the manufacturer's instructions.
Seal adapter elbow and twist into the connection of the mixer tap.
Push the union nut and clamping ring onto the pipe.
Screw in the pipe tight with the union nut onto the adapter elbow.
Lay the free pipe end up to the connection place of the bathtub
drain/overflow.
Handling
Multiplex Trio F drain/overflow functional unit
12 from 25