Mount the sealing element.
Check the sealing element for firm seat.
Press the drain into the connection element until it snaps home.
With mounting heights of max. 70 mm, align the base unit in the
mortar bed.
Provide mortar bedding to secure the drain against slipping.
Handling
Advantix odour trap