for Advantix shower channel, for installation height of 95 mmand up, reconstruction model can be cut to size subsequently
Model
Year built:
4982.92
from 04/2016
en_INT
Advantix odour trap
Instructions for Use
Page 1: ...Advantix shower channel for installation height of 95 mm and up reconstruction model can be cut to size subsequently Model Year built 4982 92 from 04 2016 en_INT Advantix odour trap Instructions for...
Page 2: ...Advantix odour trap 2 from 16...
Page 3: ...6 2 2 Intended use 6 2 2 1 Areas of use 6 2 2 2 Media 6 2 2 3 Drainage capacity 7 2 3 Product description 7 2 3 1 Overview 7 2 3 2 Technical data 8 3 Handling 9 3 1 Assembly information 9 3 1 1 Import...
Page 4: ...ot extend to possible operating instructions The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use 1 2 Labelling of...
Page 5: ...or in Germany e g DIN DVGW Some passages in the text may refer to technical codes in Europe Germany These should serve as recommendations in the absence of corresponding national regulations The relev...
Page 6: ...drain is designed for small to medium volumes of water which occur in e g residential building Technical information see Chapter 2 3 2 Technical data on page 8 The drain is suitable for horizontal con...
Page 7: ...e grate is 0 5 l s The drainage capacity at an accumulation height of 20 mm above the grate is 0 55 l s 2 3 Product description 2 3 1 Overview 1 2 3 4 5 1 Odour trap immersion pipe 2 Odour trap insert...
Page 8: ...t DN40 DN50 Drainage capacity Chapter 2 2 3 Drainage capacity on page 7 Dimensions and installa tion height Chapter 3 1 2 Installation dimen sions on page 9 Water seal level 50 mm Load class K 300 kg...
Page 9: ...2 2 3 Drainage capacity on page 7 n Check if the installation height of the drain corresponds with the planned floor construction n Ensure that the required connection line is installed with the neces...
Page 10: ...to size Requirements n You want to cut the odour trap to the size of the reconstruction model Cut the casing at the sawing groove provided for this purpose Cut the odour trap insert at the sawing gro...
Page 11: ...provided for this purpose You have cut the odour trap to the size of the reconstruction model 3 2 2 Mounting the odour trap Check the connection element for soiling clean if necessary Determine the s...
Page 12: ...for firm seat Press the drain into the connection element until it snaps home With mounting heights of max 70 mm align the base unit in the mortar bed Provide mortar bedding to secure the drain again...
Page 13: ...Align it horizontally in all directions INFO The drain is 180 rotatable Connect the drain DN40 or the adapter element DN50 to the drainage system The wastewater pipe can also be laid under the shower...
Page 14: ...ap 90 to the right Mount and grease the sealing element Insert the odour trap immersion pipe The odour trap insert has been fastened Check the base unit including the drain and the connection line for...
Page 15: ...he site protection Remove the lower protective foil and stick the adhesive points on Shorten the second part of the site protection if applicable and mount it Remove the top protective foil of the adh...
Page 16: ...upper edge of the flange with screed 3 3 Disposal Separate the product and packaging materials e g paper metal plastic or non ferrous metals and dispose of in accordance with valid national legal requ...