Remove protective plug.
Remove sliding ring and sealing from the protective plug.

Push the union nut, sliding ring and sealing onto the inlet pipe.
Push inlet pipe at least 1.5 cm deep into the drain inlet.
Screw the inlet pipe with the coupling onto the drain inlet.

Position the drain at the desired height at the place of use. If neces‐

sary, raise or lower in the existing floor using suitable material.
Align drain horizontally using a spirit level.

Secure the drain in such a way that it cannot shift when the subse‐

quent works are applied.
Work the drain into the screed or floor covering.

Mounting the drain

Handling

Advantix bathroom drain

12 from  15

Summary of Contents for 4921.4

Page 1: ...Model Year built 4921 4 from 01 1987 en_INT Advantix bathroom drain Instructions for Use...

Page 2: ...Advantix bathroom drain 2 from 15...

Page 3: ...Product description 7 2 3 1 Overview 7 2 3 2 Technical data 7 2 4 Information for use 8 2 4 1 Installation variations 8 2 5 Required accessories 8 3 Handling 10 3 1 Assembly information 10 3 1 1 Impo...

Page 4: ...on does not extend to possible operating instructions The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use 1 2 Labe...

Page 5: ...in Germany e g DIN DVGW Some passages in the text may refer to technical codes in Europe Germany These should serve as recommendations in the absence of corresponding national regulations The relevan...

Page 6: ...out sealing e g cellars where wastewater occurs in small quantities at irregular intervals Technical information see Chapter 2 3 2 Technical data on page 7 2 2 2 Media The drain is intended for draini...

Page 7: ...t H of the drain unit 2 3 Product description 2 3 1 Overview 1 2 3 4 6 5 1 grate 2 top can be cut to length 3 cleaning screw 4 horizontal drain socket DN 50 with ball joint 5 base unit 6 inlet DN 40 f...

Page 8: ...d in the following way n in a drill hole n in a floor recess 2 5 Required accessories Advantix tops are available in a number of sizes and variations You can also only buy an Advantix top frame and th...

Page 9: ...h also closes the drain odour tight if the water seal in the odour trap has evaporated Odour nuisance is even avoided with drains that are only seldom used Odour barriers can be found in the catalogue...

Page 10: ...responds with the planned floor construction n Ensure that the required connection line is installed with the neces sary incline to the planned installation location n If necessary supply the required...

Page 11: ...place for the connection to the wastewater system n The drainpipe has an internal sealing lip Align drain socket on the ball joint Push the drain socket into the drainpipe completely The connection to...

Page 12: ...with the coupling onto the drain inlet Position the drain at the desired height at the place of use If neces sary raise or lower in the existing floor using suitable material Align drain horizontally...

Page 13: ...he drain must be fully lined and that there must be no hollow spaces 3 2 2 Mounting the top Starting with the upper edge transfer the measured height onto the top Cut the top to the marked height Remo...

Page 14: ...ains even around the drain unit and the siphon can be removed using typical household cleaner It should be noted that the cleaning agent should be rinsed off after the prescribed soaking time There sh...

Page 15: ...w Re insert grate 3 4 Disposal Separate the product and packaging materials e g paper metal plastic or non ferrous metals and dispose of in accordance with valid national legal requirements Handling A...

Reviews: