Open the hinged adapter jaw via the handle and pull the Press
Booster off the press ring.
INFO! If you cannot fully open the hinged adapter jaw of the
Press Booster via the handle, carry out another stroke with
the press machine (reset stroke). After a brief startup of the
press machine, the press machine and the Press Booster
return to their starting positions.
3.4
Interrupting pressing
Should it be impossible to fully complete the pressing, you can manually
loosen the Press Booster from the press ring.
Keep the button for manual unlocking pressed until the piston has
fully retracted and the hinged adapter jaw is without any load.
INFO! To do so, you may need to reset the press machine in
the same way.
Pull the handle at the hinged adapter jaw back.
ð
The hinged adapter jaw opens.
Aborted pressings of Megapress XL press connectors can be resumed
and completed later. This should only be done in exceptional cases and
is applicable in cases where the pressing was interrupted between the
first and second pressing, and the press ring was loosened manually.
Take the Press Booster off the press ring
Continuing an aborted pressing
Handling