![Viega 2842.5 User Manual Download Page 3](http://html1.mh-extra.com/html/viega/2842-5/2842-5_user-manual_1016554003.webp)
3 of 4
Viega Flash Shower Valve User Guide
UG-PP 530594 0520 Flash Shower Valve 2842-5
For back to back installation, follow
steps mentioned above. Reversal
of Hot/Cold water supplies is
accomplished by rotating cartridge (supplied
with trim) 180° during installation.
CAUTION!
After valve installation, inspect the
VALVE BODY for any debris. It can
damage Pressure Balance Valve cartridge.
CAUTION!
Turn off hot and cold water supplies
before beginning.
Thin Wall Installation
■
See Roughing-in diagram before starting.
■
Finished wall should allow for a 3½ diameter
opening (Use PLASTER GUARD for guidance).
■
Remove PLASTER GUARD (8), rotate 90˚
counter clockwise and install the two screws.
(Thin wall text should be on top)
■
Use SELF-CENTERING HOLE GUIDES (9) as
a guide for thin wall install.
■
LOCKING SCREW (10) keeps valve in place
when installing. Completely Thread LOCKING
SCREW (10) onto PLASTER GUARD (8).
■
During the installation, make sure to position
the Locking feature screw as shown in Figure
A below. Once the valve is positioned on the
Thin Wall, turn counterclockwise as shown in
Figure B to secure VALVE BODY (2) in place.
■
Connect HOT and
COLD water supplies.
See
to make a ProPress
connection.
■
Connect RISER PIPE (1)
to VALVE BODY (2) top
outlet marked “UP”.
■
Connect TUB FILLER
PIPE (3) to bottom outlet.
Side View
3½
1
2
8
9
10
10
10
3
Hot
Fig. A
Fig. B
Unlock
Lock
Cold
Hex
Wrench
4 mm
6
ProPress ½ to 2
Product Instructions