Fig. 2: Specification plate
1 Manufacturer logo with address
2 Nominal force
3 Year of manufacture
4 Permitted constant operation ≤ 30 min
5 Nominal output
6 Maximum three pressings per minute (≤ DN 54)
7 QR code
8 Permitted frequency range
9 Permitted voltage area
10 Article number / serial number
11 Type designation for the press machine
For explanations on the symbols, see
Chapter 1.2 ‘Labelling of advi‐
sory text and safety symbols’ on page 3
2.4.2
Technical data
Nominal output
450 W
Voltage
220–240 VAC
Frequency
50–60 Hz
Machine monitoring
hydraulic
Acoustic power level max.
87 dB(A)
1)
Sound pressure on ear
76 dB(A)
1)
Oscillation level
< 2.5 m/s
2
2)
Power transmission
hydraulic
Thrust on piston
32 kN
Switch-on duration
Maximum three pressings per
minute
Permitted continuous operation
≤ 30 min
1)
measurement uncertainty 3 dB(A)
2)
measurement uncertainty 1.5 m/s
2
Data on the specification plate
Product information
Pressgun 6B press machine with mains connection
11