Fault
Cause
Solution
Actuating the Start
button does not
trigger pressing.
The press machine is
not switched on.
Press the On/Off
button. The green
LED is lit.
The battery is too
weak.
Fully charge the bat‐
tery.
The battery or mains
adapter is not prop‐
erly inserted.
Check it is correctly
located in the
mounting bracket.
The mains cable of
the mains adapter is
not connected to the
mains.
Connect it to the
power supply.
The power supply is
not correct.
Establish the power
supply as specified by
the manufacturer.
Contact an authorised service partner if the press machine does not
start after carrying out the measures above.
3.6
Care and maintenance
The tools are subject to normal wear and tear; for this reason, they must
be maintained in regular intervals. Only service partners authorised by
Viega may service and maintain the tools. See
tion and maintenance’ on page 19
.
3.6.1
Cleaning the press tools
NOTICE!
Damage due to fluids!
Make sure that no fluids get inside the press machine.
Never dip the press machine into fluids.
Requirements:
n
The press machine is not energised (disconnected from the mains or
rechargeable battery has been removed).
n
No press jaw is inserted.
▶
Wipe the press machine down with a slightly damp cloth.
▶
Clean the press rolls of the roller head dry and then treat with main‐
tenance oil (art. no. 667 924).