Vidos Duo M1022 User Manual Download Page 3

1.Parts and Functions

2.Monitor Mounting

145~160 cm

LCD Screen

Microphone

Talk/Mon Button

Menu Button

Up Button

Close Button

Return Button
Down Button

Mute Button/Indicator

Unlock Button

Connection Port

Mounting Hook

1

2

sw+

sw-

RING

GND

NC

3

ON

L1

L2

DIP

4

5

6

SW+,SW-:

 

Door  bell  call  button 

connection port.

Ring,GND:

 

Extra buzzer connection 

port.

NC:

 Reserved.

L1,L2:

 Bus terminal.

DIP  switches: 

T otal  6  bits  can  be 

configured.

Bit1~Bit5: 

Used to User Code setting.

Bit6:

 Set to ON 

if the monitor is at the 

end of the line or works with M-SM4. 

Otherwise, set to OFF.

Terminal Description

1

2

sw+

sw-

RING

GND

NC

3

ON

L1

L2

DIP

4

5

6

1

2

SW+

SW-

RING

GND

NC

3

ON

L1

L2

DIP

4

5

6

4. Basic Door Release Operation

1.  Press 

CALL

 

button  on  outdoor  station,  the 

Monitor rings, meanwhile, the screen displays the 

visitors' image.

2.  Press

 

Talk/Mon

 

Button on monitor, you 

can  communicate  hands  free  with  the  visitor 
for 90 seconds.  After finishing communication, 
press

 

Talk/Mon

 

button again(or press

Close

 

Button)  to  end  the  communication.  If 

nobody answers the phone, the screen will be turned off automatically after 40 seconds.  

3.  During talking state, Press

 

Unlock

 Button to release the first door.

4.  When the monitor is in standby mode, press

 

Talk/Mon

 

Button (or select 

Monitor 

By Select

 

button on main menu, press 

 

Menu  Button to confirm, and then it will 

enter the select a camera page, then you can use 

 

 

Button to select the camera you 

want), the screen can display the view of outside.

1.  Use the screws to fix the Mounting Bracket on the 

mounting box.(fitting accesories 

includes a Bracket (Two pieces of 4X25 screws are needed for fastening the Mounting 

Bracket), Special 2 wire connectors to connect with Monitor)

2.  Wire the system correctly(see the later connection

 

chapter) then hang the Monitor on 

the Mounting Bracket firmly.

  00:23  

  DS-1

3. Main Menu

Press

 

Menu

 

/

Close

 

button,  in 

standby mode, the main menu page will be 

shown as follows:

4

5

Summary of Contents for Duo M1022

Page 1: ... door intercom M1022 W 20180827 USER S MANUAL 4 VIDEO HANDS FREE COLOR TFT MONITOR Firma Handlowa Wena Al Jerozolimskie 311 05 816 Reguły near Warszawy Poland tel 48 22 8370286 48 22 8174008 e mail biuro vidos pl www vidos pl ...

Page 2: ...ystem It works well with all door stations within the dual wire system The monitor is provided with features to control 2 relays CHRACTESISTICS OF THE SYSTEM VIDOS is a state of the art solution characterised by its exceptional ease of configuration and installation The system operation is based on the simplicity of connection through 2 non polarity wires only It can be extended with additional opt...

Page 3: ...mmunicate hands free with the visitor for 90 seconds After finishing communication press Talk Mon button again or press Close Button to end the communication If nobody answers the phone the screen will be turned off automatically after 40 seconds 3 During talking state Press Unlock Button to release the first door 4 When the monitor is in standby mode press Talk Mon Button or select Monitor By Selec...

Page 4: ...to operate it such as monitor talk and unlock 3 Simutaneously Calls from outdoor station will be diverted toyour telephone immediately At this mode the monitor won t shut off when TPC GSM TPS divert sucessfully but if the monitor answers the call at this time TPC GSM TPS will quit absolutely 4 Setup Tel Numbers Select this item to edit the divert numbers you want Monitor By Select Main Menu Divert...

Page 5: ... Ring Ring Ring Ring Ring Tune Tune Tune Tune Tune Tune Tune Tune Use button to selete Light item then press Menu button to confirm Use button to selete Setup item then press Menu button to confirm Use Button to selete the item you want then press Menu button to confirm Use Button to selete the item you want then press Menu button to confirm Light Main Menu Restore About Setup Resto Resto Resto Resto ...

Page 6: ...r at the end of the line The DIP swiches are used to configure the User Code for each Monitor Bit 1 to Bit 5 are used to User Code setting Bit 6 is line terminal switch which have to be set to ON if the Monitor is in the end of the line bus otherwise set to OFF The end of the lin e is terminal that no other section will start from it 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 ...

Page 7: ...e value press Return Button to quit the adjust page Bright 5 12 Basic Connection door station BUS IM BUS DS P26 40 AC Doorbell Button Switch 1 2 sw sw RING GND NC 3 ON L1 L2 DIP 4 5 6 14 Specifi cations 12 13 value to get the best image you like Power supply DC 20 28V Power consumption Standby 0 17W Working 4 7W Communication Hands free Screen 4 Inch digital color TFT Display Resolutions 480 3 R G ...

Page 8: ...instructions the product has been used or left in improper conditions excessive humidity too high or low temperature sunlight etc maintenance and operational condition which are different from the ones specified in the product operating instructions mechanical chemical and thermal damage damage caused by external forces e g overvoltage in the electrical network atmospheric discharges flood fire damage...

Reviews: