background image

130A/160A/180A/200A/250A INVERTER MMA DC WELDING MACHINE        ENG

EXPLOSIVE VIEW OF WD06011018

PART LIST OF WD06011018

NO

DESCRIPTION

Q’TY

NO

DESCRIPTION

Q’TY

1

Handle

1

17

Fan

1

2

Housing

1

18

Output inductance

1

3

Current-carrying plate

1

19

Transformer

1

4

Current selector knob

1

20

Bridge rectifiers

1

5

Shade of LED

2

21

Radiator

1

6

Digital display instrument

1

22

IGBT single tube

4

7

Front cover

1

23

Radiator

2

8

Base plate

1

24

Support bar of IGBT radiator

1

9

Quick connector

2

25

Rear cover

1

10

Radiator

1

26

Fan

1

11

Insulation paper plate

1

27

Cable and plug

1

12

Current-carrying plate

1

28

Cable gland

1

13

Support bar of rectifier radiator

1

29

Power switch   

1

14

Main PCB

1

30

Belt

1

15

Control PCB

1

31

Ground clamp with cable

1

16

Fast recovery diode

4

32

Electrode holder with cable

1

18

Summary of Contents for WD060111013U

Page 1: ...INVERTER MMA DC WELDING MACHINE WD060111013U WD060111016 WD060111018 WD060111020 WD060111025 130A 160A 180A 200A 250A...

Page 2: ...ng a VIDO product We are confident that you will appreciate the quality of the product and you will be entirely satisfied with your purchase Please read carefully the user safety and operating instruc...

Page 3: ...3 WD060111013U WD060111016 WD060111018 WD060111020 WD060111025 1 7 2 4 5 3 6...

Page 4: ...4 10 200 100 WD060111013U WD060111016 WD060111018 WD060111020 WD060111025 x 9 1 8 10 2 3 6 5 4 9 8 7 11 10...

Page 5: ...pc 2 Ground clamp with cable 1pc 3 Protective mask 1pc 4 Hammer brush 1pc 5 Belt 1pc We recommend that you purchase your accessories from the same store that sold you the welding machine Use good qual...

Page 6: ...frozen pipes Turn off all equipment when welder not in use Fumes can be dangerous Fumes emitted from the welding process displace clean air and can result in injury or death Do not breathe in fumes em...

Page 7: ...ts that are oil free with no pockets or cuffs that will collect sparks Do not have on your person any items that are combustible such as lighters or matches Keep work lead connectedas close to the wel...

Page 8: ...of the cable should be bigger to reduce the lower of the cable voltage GROUNDING INSTRUCTIONS This welding machine should be grounded while in use to protect the operator from electric shock The weldi...

Page 9: ...risk Wear eye protection Wear ear protection Direct correction DC Single phase static frequency converter transformer rectifier Waste electrical products should not be disposed of with household waste...

Page 10: ...d voltage 85V DC 85V DC 85V DC Output range 10 130ADC 10 160A DC 10 180ADC Duty cycle 60 130A 60 160A 60 180 A m m 0 4 6 1 m m 0 4 6 1 m m 0 4 6 1 r e t e m a i d e d o r t c e l E Ingress protection...

Page 11: ...output cable a The electrode holder cable is connected to the output terminal of the welding machine Insert the connector with the key lining up with the keyway and rotate approximately 1 3 turn cloc...

Page 12: ...the electrode in relation to the workpiece should be between 600 and 800 degrees This will allow for good penetration with minimal spatter 5 Striking the arc Warning Exposure to a welding arc is extr...

Page 13: ...ld speed is too fast B Weld speed is too slow C Arc is too long D Ideal weld Note A solid weld bead requires that the electrode be moved slowly and steadily along the weld seam Warning Electric shock...

Page 14: ...Remove the plug from the socket before carrying out any adjustment servicing or maintenance 1 Never use water or chemical cleaners to clean your welding machine Only wipe clean with a dry cloth 2 Und...

Page 15: ...upply is lower or higher than required range Contact your local power supply enterprise Electrode holder or ground cable getting hot Output connections getting hot Weld cable connections loose Check t...

Page 16: ...l PCB 1 4 Fan 1 18 Current carrying plate 1 5 Rear cover 1 19 Current carrying plate 1 6 Power switch 1 20 Base plate 1 7 Support bar of IGBT radiator 1 21 Quick connector 2 8 Radiator 2 22 Currentsel...

Page 17: ...urrent carrying plate 1 5 Rear cover 1 20 Base plate 1 6 Fan 1 21 Quick connector 2 7 Radiator 1 22 Front cover 1 8 Bridge rectifiers 1 23 Current carrying plate 1 9 Radiator 2 24 Currentselectorknob...

Page 18: ...5 Shade of LED 2 21 Radiator 1 6 Digital display instrument 1 22 IGBT single tube 4 7 Front cover 1 23 Radiator 2 8 Base plate 1 24 Support bar of IGBT radiator 1 9 Quick connector 2 25 Rear cover 1 1...

Page 19: ...ar of IGBT radiator 1 22 Nut 1 5 Radiator 2 23 Shade of LED 2 6 Power switch 1 24 Current selector knob 1 7 IGBT single tube 4 25 Current carrying plate 1 8 Cable gland 1 26 Current carrying plate 1 9...

Page 20: ...Shade of LED 2 21 Radiator 1 6 Digital display instrument 1 22 IGBT single tube 4 7 Front cover 1 23 Radiator 2 8 Base plate 1 24 Support bar of IGBT radiator 1 9 Quick connector 2 25 Rear cover 1 10...

Page 21: ...WD060111013U WD060111016 WD060111018 WD060111020 WD060111025 21...

Page 22: ...WD060111013U WD060111016 WD060111018 WD060111020 WD060111025 22...

Page 23: ...WD060111013U WD060111016 WD060111018 WD060111020 WD060111025 23...

Page 24: ...MADE IN CHINA Copyright WIDO Machinery Co Ltd All rights reserved www widopt com...

Reviews: