background image

66250865-EN
V 3.4
31/08/16

VIDEOKIT
VK8K/6256 SERIES

“6 Wire” bus one way, two way videokit

Installation handbook

VK8K
VK8KC

6256

We recommend
This equipment is installed by a 
Competent Electrician, Security or 
Communications Engineer.

English

Summary of Contents for VK8K-1/6256

Page 1: ...1 08 16 VIDEOKIT VK8K 6256 SERIES 6 Wire bus one way two way videokit Installation handbook VK8K VK8KC 6256 We recommend This equipment is installed by a Competent Electrician Security or Communicatio...

Page 2: ...door open and conversation time Expandable to 4 entrance panels requires an additional relay Art 506N for each entrance panel Facility for the connection of a codelock Art 8800 Programmable number of...

Page 3: ...unit 1 Art 8855 Flush mounting box 1 Art 8875 Rainshield 1 Colour videophone Art 6256 1 Power supply Art 850K VK8K 1S 6256 surface mounting 1 Outdoor station composed of 1 Art 8833 1 DN C 1 button cam...

Page 4: ...Rainshield 1 Colour videophone Art 6256 1 Power supply Art 850K VK8KC 1S 6256 surface mounting 1 Outdoor station composed of 1 Art 8833 1 DN C 1 button camera unit 1 Art 8800 Codelock module 1 Art 88...

Page 5: ...he relevant screws When all connections are made restore the mains CABLE SIZE Video connections and Audio connections must be wired in twisted pair pair the video lines terminals signals V1 and V2 pai...

Page 6: ...g the conversation it is not possible to open the door but the key LED on the door station switches on for the program med time Incorrect position of J2 jumper Electriclockwiresunconnectedorinshort Wr...

Page 7: ...wise to increase or anti clockwise to decrease Trimmer to adjust the microphone volume Rotate clockwise to increase or anticlockwise to decrease SETTINGS DIP SWITCH JUMPERS 4 WAY DIP SWITCH First two...

Page 8: ...the door open command we suggest to use a 12Vac dc 1A max electric lock Setting dry contacts operating mode when the speaker unit receives the door open command the NO terminal will be internally lin...

Page 9: ...press ENTER The red LED will illuminate Confirm ENGINEER S CODE typing again the same or type the new code 4 to 8 digits then press ENTER Melody Press ing twice the ENTER button without changing the E...

Page 10: ...ms indicated on each schematic and follow these General Directions for Installation The system must be installed according to national rules in force in any case the running of cables of any intercom...

Page 11: ...ess Enter Press Enter Repeat steps for relay 2 and relay 3 YES NO Relay code 4 8 dig its operate the door or gate Two digits 01 99 sec or 00 for remain open ART 8800 TERMINALS SW1 Relay 1 command sign...

Page 12: ...wiring diagram provided Check the installation and if necessary adjust speech levels using volume controls L Fig 9 11 Lever the support R Fig 10 upwards and fix it to the back box with the screw M Fig...

Page 13: ...Fig 2 E H Fig 5 H E Fig 8 M P N Fig 11 Fig 14 D Fig 3 F Fig 6 L K I Fig 9 W J Fig 12 13 VK8K 6256 Series 6 wire Bus videokit VK8K 6256 Series Installation handbook EXAMPLE INSTALLING A TWO MODULE OUTD...

Page 14: ...e speech is also live and the door can be opened by pressing Door open intercommunicating call button With the handset lifted and speech lines open to the entrance panel press this button to open the...

Page 15: ...partment Address OFF 1 ON 2 Switches 2 3 Extension Address OFF OFF 1 ON OFF 2 OFF ON 3 ON ON 4 Switch 4 Intercommunication OFF Between videophones of the two apartment ON Between videophones in the sa...

Page 16: ...signal 1 sync V2 Balanced video signal 2 sync 24Vac 1A max power input LB Local call input 5V in standby 0V to trigger SB Service button open collector active low output The button goes active when t...

Page 17: ...make the holes A insert the wall plugs B and fix the base with the screws C feeding the wires D into the hole E If you have used the box 503 fix the base to the wall through the holes F using the scre...

Page 18: ...ant connection board then after a few seconds reconnected again to allow the recognizing of the new setting All diagrams shown are valid for B W or colour systems with surface or flush mount door stat...

Page 19: ...vk8k62h 002 dwg 17 11 2015 17 11 2015 Local Bell Push to Exit Door Monitor Art 8833 1 Using Electric Lock 12Vdc 0 3A Max Con serratura elettrica 12Vdc 0 3A Max Art 8833 1 In caso di modifica alle imp...

Page 20: ...di modifica alle impostazioni dei dip switch del videocitofono o del posto esterno togliere temporaneamente l alimentazione di rete In order to make the system recognize any modification of the video...

Page 21: ...aneamente l alimentazione di rete In order to make the system recognize any modification of the videophone s and outdoor station s dip switch setting temporarily disconnect the system from the mains a...

Page 22: ...Art 8833 2 In caso di modifica alle impostazioni dei dip switch del videocitofono o del posto esterno togliere temporaneamente l alimentazione di rete In order to make the system recognize any modifi...

Page 23: ...vk8k62h 006 dwg 01 12 2015 01 12 2015 Local Bell Affinche qualsiasi modifica alle impostazioni dei dip switch del videocitofono o del posto esterno venga riconosciuta dal sistema necessario togliere...

Page 24: ...o del posto esterno togliere temporaneamente l alimentazione di rete In order to make the system recognize any modification of the videophone s and outdoor station s dip switch setting temporarily dis...

Page 25: ...del videocitofono o del posto esterno togliere temporaneamente l alimentazione di rete In order to make the system recognize any modification of the videophone s and outdoor station s dip switch sett...

Page 26: ...le impostazioni dei dip switch del videocitofono o del posto esterno togliere temporaneamente l alimentazione di rete In order to make the system recognize any modification of the videophone s and out...

Page 27: ...rt 8833 2 ID 2 Art 8833 2 ID 1 Push to Exit Push to Exit 18Vdc 230V ART 323 18 20V GND 1 2 V1 V2 Videx Electronics S p A Via del Lavoro 1 63846 Monte Giberto FM Phone 39 0734 631669 Fax 39 0734 631669...

Page 28: ...prey Trinity Park Trinity Way LONDON E4 8TD Phone 44 0870 300 1240 Fax 44 020 8523 5825 www videx security com marketing videx security com Northern UK office VIDEX SECURITY LTD Unit 4 7 Chillingham I...