background image

66251400-EN - V5.1 - 31/08/20

- 16 -

VK4K/6358 Series “6 wire Bus” videokit

VK4K/6358 Series - Installation handbook

PROGRAMMING

• Enter 

the 

ENGINEER’S CODE

: first time type six times 

1

 (

111111

 

factory preset) and press 

ENTER

 (The red LED will illuminate);

• Confirm 

ENGINEER’S CODE

 (typing again the same) or 

type the new code (4 to 8 digits) then press 

ENTER

 (Melo-

dy). Pressing twice the 

ENTER

 button without changing the 

ENGINEER’S CODE

, will exit from the programming;

•  Enter the code (4 to 8 digits) to enable 

RELAY 1

 or re-enter the 

existing code then press 

ENTER

 (Melody);

• Enter the 

RELAY 1

 operation time (2 digits 01 to 99 

I.E.

 05=5 

seconds, 00= remain open time) or re-enter the existing time 
then press 

ENTER

 (Melody);

•  Enter the code (4 to 8 digits) to enable 

RELAY 2

 or re-enter the 

existing code then press 

ENTER

 (Melody);

• Enter the 

RELAY 2

 operation time (2 digits 01 to 99 

I.E.

 05=5 

seconds, 00= remain open time) or re-enter the existing time 
then press 

ENTER

 (Melody);

•  Enter the code (4 to 8 digits) to enable 

RELAY 3

 or re-enter the 

existing code then press 

ENTER

 (Melody);

• Enter the 

RELAY 3

 operation time (2 digits 01 to 99 

I.E.

 05=5 

seconds, 00= remain open time) or re-enter the existing time 
then press 

ENTER

 (Melody);

•  The system is ready to use (the red LED will be off ).

PROGRAMMING NOTES

•  After pressing enter following a command, press 

ENTER

 a fur-

ther twice to exit the programming menu.

RETURN SYSTEM TO PRESET ENGINEER’S FACTORY CODE

•  Turn off power to code lock;
• Keep 

ENTER

 button pressed while turning the power back on;

• Release 

ENTER

 button;

•  The engineer’s code is now set to 

111111 

(six times one).

OPERATION

•  Type in the programmed code and press 

ENTER

;

•  If the code is correct, the green LED will illuminate for approx. 2 seconds and the relay relevant to the code will operate for the 

programmed time;

•  If a wrong code is entered, a continuous melody will sound for 4 or more seconds, according to the number of mistakes;
•  To switch off any relay while operating, type in the relevant code then press the 

CLEAR

 button;

OPERATION NOTES

•  To operate relays together, set the same code for each relay;
•  If a wrong code is entered, the system will lock out for 5 seconds which will increase each time a wrong code is entered. The system will 

operate only when the correct code is entered.

ADHESIVE GASKET PLACEMENT

Apply the 

Y

 seal as shown in 

Fig. 5

.

ANTI-TAMPERING LOCKS FIXING

Fit the anti-tampering locks 

W

 as shown in 

Fig. 6

.

Y

G

Fig. 5  

 

W

Fig. 6  

 

ENTER THE 

"ENGINEER’S CODE"

CONFIRM 

OR CHANGE 

"ENGINEER’S CODE"

ENTER

"ACCESS 1 CODE"

ENTER

"ACCESS 2 CODE"

ENTER

"ACCESS 3 CODE"

ENTER

"ACCESS 1 TIME"

ENTER

"ACCESS 2 TIME"

ENTER

"ACCESS 3 TIME"

SYSTEM

READY TO USE

First time six times 
1 “111111”  factory 
preset

Type again six times 
“1” or the new en-
gineer’s code 4 to 8 
digits

Code to enable relay 1
4 to 8 digits

Code to enable relay 2
4 to 8 digits

Code to enable relay 3
4 to 8 digits

Two digits (01 to 99) 
i.E. 05=5 Seconds
00= remain open

Two digits (01 to 99) 
i.E. 05=5 Seconds

Two digits (01 to 99) 
i.E. 05=5 Seconds

Red led will be off

Press Enter
(Red LED will 
be ON)

Press Enter
(melody)

Press Enter
(melody)

Press Enter
(melody)

Press Enter
(melody)

Press Enter
(melody)

Press Enter
(melody)

Press Enter
(melody)

Art. 4901 

 Digital codelock module

Summary of Contents for Videokit VK4K

Page 1: ...VIDEOKIT VK4K 6358 SERIES 6 Wire bus one way two way videokit Installation handbook 6358 We recommend This equipment is installed by a Competent Electrician Security or Communications Engineer VK4KR0...

Page 2: ...r Some diagrams show how to connect a 12Vdc electric lock these directions are suitable for all diagrams in this manual Each time a setting is changed on a videophone address extension number of rings...

Page 3: ...f 1 Art 4833 1 1 button camera unit 1 Art 4851 Flush mounting box 1 Colour videophone Art 6358 1 Power supply Art 850K VK4K 1S 6358 surface mounting 1 Outdoor station composed of 1 Art 4833 1 1 button...

Page 4: ...ur videophone Art 6358 1 Power supply Art 850K 1 Card format fob Art 955 C 2 Tag for mat fobs Art 955 T VK4KX 1S 6358 surface mounting 1 Outdoor station composed of 1 Art 4833X 1 1 button camera unit...

Page 5: ...h mounting box 1 Colour videophone Art 6358 1 Power supply Art 850K VK4KC 1S 6358 surface mounting 1 Outdoor station composed of 1 Art 4833 1 1 button camera unit 1 Art 4901 Codelock module 1 Art 4882...

Page 6: ...tions then restore the mains CABLE SIZE Video connections and Audio connections must be wired in twisted pair pair the video lines terminals signalsV1 andV2 pair the audio lines terminals signals 1 an...

Page 7: ...ng the conversation it is not possible to open the door but the key LED on the door station switches on for the program med time Incorrect position of J2 jumper Electriclockwiresunconnectedorinshort W...

Page 8: ...DS When illuminated indicates that it is not possible to make a call because a call or a conversation is in pro gress from the outdoor station from which you are calling or from another outdoor statio...

Page 9: ...r Setting up H L J1J2J3J4 Bothbuttonscall thesamevideo phone Address1 H L J1J2J3J4 Each button calls a different videophone J4 BUILT IN RELAY BACK EMF PROTECTION MOV Jumper Setting up H L J1J2J3J4 NC...

Page 10: ...mains illuminated BIP Note the module emits a low pitched continuous beeping sound if an already programmed location is selected BIIIIIIP 5 Repeat steps 2 to 4 for to program further tags 6 To exit pr...

Page 11: ...the LED flashes for a num ber of times that corresponds to the key number then the module emits another high pitched beep sound and the LED remains fixed on BIP BIP 3 Repeat step 2 to identify other...

Page 12: ...causethe capacitivedischarge tomalfunctionintime Incase theelectriclockisusedinverydustyenvironmentsorinpeculiarclimateconditions wesuggesttousethelockindrycontactmode 12Vac dc 1A Max Fig 5 Using capa...

Page 13: ...atasig nal approx 12V in stand by approx 5V with a conver sation in progress 2 Speech line output from the microphone approx 12V in stand by approx 3V with a conversation in progress V1 Balanced video...

Page 14: ...NO relay outputs 24Vac dc 5A max 3 Programmable secret codes one for each relay Each relay can be set to be activated for a specific time 01 to 99 seconds or to work as latch Two active low inputs to...

Page 15: ...A or B A B A B or Back light on full brightness all of the time JPL removed in either Mode A B No back light the back light is completely disabled PROGRAMMING MODE 1 DEFAULT MODE JPL A Follow the ste...

Page 16: ...Release ENTER button The engineer s code is now set to 111111 six times one OPERATION Type in the programmed code and press ENTER If the code is correct the green LED will illuminate for approx 2 sec...

Page 17: ...ally closed contact NO2 Relay 2 normally open contact C2 Relay 2 common contact NC1 Relay 1 normally closed contact NO1 Relay 1 normally open contact C1 Relay 1 common contact 12 24Vac dc power input...

Page 18: ...dbook 4000 SeriesSurface and flush mounting door station installation EXAMPLE INSTALLING A FOUR MODULE OUTDOOR STATION H G H Y G C F E D B A C L H L P O N M H M M C Q P C D W N N C H fig 1 fig 8 fig 4...

Page 19: ...nd is working correctly move back the module support frames carefully fix them to the surface box using the screwdriver provided P torx end and the pin machine torx screws Q Fig 11 Note do not over ti...

Page 20: ...e the button remains pressed Privacy ON OFF button When the system is in stand by the pressing of this button activates LED switched on or disables LED switched off the privacy service The service is...

Page 21: ...the button is not pressed for 10 seconds the videomonitor will switch off The videomonitor will revert to duplex speech when another call is made LEDS Privacy on LED It illuminates when the privacy s...

Page 22: ...20Vdc Input Output As input 16 20Vdc 0 5A as output 20Vdc 0 5A max Ground reference for V terminal 1 Speech line output from microphone and data signal Approx 12V in stand by 5V during a conversation...

Page 23: ...F Fig 4 If you use the flush mounting box 503 embed it into the wall vertically at approx 140cm from the finished floor and the base 4 Following Fig 4 make the holes B insert the wall plugs C and fix...

Page 24: ...In white plastic ABS box 11x70x30mm surface mount ART 316N As Art 316 but small form factor without terminals to connect plus and minus from videophones is required an external connection of these te...

Page 25: ...66251400 EN V5 1 31 08 20 25...

Page 26: ...66251400 EN V5 1 31 08 20 26...

Page 27: ...66251400 EN V5 1 31 08 20 27...

Page 28: ...66251400 EN V5 1 31 08 20 28...

Page 29: ...66251400 EN V5 1 31 08 20 29...

Page 30: ...66251400 EN V5 1 31 08 20 30...

Page 31: ...66251400 EN V5 1 31 08 20 31...

Page 32: ...66251400 EN V5 1 31 08 20 32...

Page 33: ...66251400 EN V5 1 31 08 20 33...

Page 34: ...66251400 EN V5 1 31 08 20 34...

Page 35: ...66251400 EN V5 1 31 08 20 35...

Page 36: ...66251400 EN V5 1 31 08 20 36...

Page 37: ...66251400 EN V5 1 31 08 20 37...

Page 38: ...66251400 EN V5 1 31 08 20 38...

Page 39: ...unicipauxenm lange L utilisateurdoitdoncremettrel quipementenfinde vieauxcentresdecollecteappropri soulerestitueraurevendeurlorsdel achatd unnouveautyped quipement quiva lent danslerapportdeun un Depl...

Page 40: ...Center Twente BCT Grotestraat 64 NL 7622 GM Borne www videxintercom nl info videxintercom nl El producto lleva la marca CE que demuestra su conformidad y puede ser distribuido en todos los estados mi...

Reviews: