background image

 
 
 

PAGE 4 of 24             AUDIO/VIDEO VANDAL RESISTANT TECHNICAL MANUAL 

 

VER1.1 

MANUAL INTRODUCTION 

 
The information in this manual is intended as an installation and commissioning guide for 
the standard range of vandal resistant door panels, to be used with standard AC buzzer 
telephones or with vandal resistant video panels using the Art.890 controller. This manual 
should be read carefully before the installation commences. Any damage caused to the 
equipment due to faulty installations where the information in this manual has not been 
followed is not the responsibility of Videx Security Ltd. 
 
VIDEX run free training courses for engineers who have not installed this system before. 
Technical help is also available on 0191 224 3174 during office hours or via e-mail 
[email protected]
 

SYSTEM INTRODUCTION 

 
This system can be used for single entrances or multiple entrances. The system has no 
limit on the number of apartments for which it can control or the number of entrance points 
that can be connected together, although we suggest using this system on small to 
medium sized installation of no more than 20 apartments and three entrances. 
 

SYSTEM COMPONENTS 

 
A standard audio system will comprise of a door panel, power supply and audio 
telephones. A standard video system will comprise of a door panel, video controller, power 
supply, video splitters and videophones. The individual parts are described below. 
 

DOOR PANELS

 

 
A vandal resistant door panel will consist of an amplifier module, button connector board 
and ‘n’ number of buttons. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Speech volume adjustments are carried out at the door panel using a small trimmer driver.  
 
 
 
 

 

 

 

 

 

 

Connection Function  

Connection  Function 

Receive speech from apartment 

  LOCK 

Spare connector terminals 

Transmit speech to apartment 

  CB 

Common of call buttons 

+12Vdc input 

  A 

Spare connection terminal 

0V (Ground) 

  1 

Call button 1 connection 

 

 

  2 

Call button 2 connection 

 

    3 

Call button 3 connection 

 

 

  4 

Call button 4 connection 

Camera module (Art.830 & 830C)

 

 

  5 

Call button 5 connection 

Connection Function 

  6 

Call button 6 connection 

+20Vdc input 200mA 

(400mA - 830C)

    7 

Call button 7 connection 

F1 

0V 

  8 

Call button 8 connection 

Centre core of coax video cable 

  9 

Call button 9 connection 

Screen of coax video cable 

  10 

Call button 10 connection 

SB 

+8-12Vdc camera heater 

  TRADE 

Trade button connections 

 

Adjustment for 

speech volume level 

at the door station 

Adjustment for 

speech volume at the 

apartment 

Amplifier module (Art.437 or Art.537) 

Connector PCB (CB) 

Summary of Contents for VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEM

Page 1: ...TECHNICAL MANUAL EDITION 1 1 VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEMS...

Page 2: ...PAGE 2 of 24 AUDIO VIDEO VANDAL RESISTANT TECHNICAL MANUAL VER1 1...

Page 3: ...system block diagram 14 Video system block diagram 15 Testing the installation 15 Panel care 15 Accessories connection guide 16 Single entrance single button audio wiring diagram 17 Single entrance mu...

Page 4: ...ances SYSTEM COMPONENTS A standard audio system will comprise of a door panel power supply and audio telephones A standard video system will comprise of a door panel video controller power supply vide...

Page 5: ...button video codelock 200mm W x 420mm H x 50mm D 1 BUTTON C 2 BUTTON B D Note Also available in 125mm 220mm panel style 3 BUTTON A C E 4 BUTTON B D G I 5 BUTTON A C E G I 6 BUTTON A C E F H J 7 BUTTON...

Page 6: ...3Vac 1A Max 230 Mains in Live connection 0 Mains in Neutral connection Terminal Function Power input 24Vac Power input 13Vac 1 Switched 20Vdc to videophones Only on during a call 2 Switched negative f...

Page 7: ...C 0V C 0V trigger input From 4V to 0V C volts trigger input From 8V up to 30V D Switched 20Vdc output via diode BST GMT digital time clock This time clock operates from a 12Vac or dc power supply The...

Page 8: ...10 Centre core of coax to apartments 11 Screen of coax to apartments 12 Switched 20Vdc from Art 890 7A Transmit speech to door A 7B Transmit speech to door B 8A Receive speech from door A 8B Receive s...

Page 9: ...anel 3 0V 4 Not used Electronic call tone input 5 Lock trigger Switched 0V 6 Call line 13Vac input to trigger buzzer 8 Dry contact switch 9 The Art 3102 AC buzzer telephone includes a lock release pus...

Page 10: ...An Art 3980 back plate is required with this videophone CONNECTIONS Function 1 12V out to power video splitter 2 Camera recall 3 Spare button 4 20V power input 5 Door release command 6 Transmit speec...

Page 11: ...en LED 14 Select input to switch on videophone 15 Call tone input 16 Common of spare buttons 17 Spare button 18 12V to power videophone privacy DIP SWITCH SETTINGS 8 Way dip switch Switches 1 5 Mute D...

Page 12: ...e the mains Isolate the mains before carrying out any maintenance work on the system All intercom and access control cables must be routed separately from the mains Extension sounder for an apartment...

Page 13: ...nals 1 2 6 10 and for terminals 3 5 3 Connections for power supply output to door panel and lock release connections 50m 100m Connections 0 5mm 0 75mm The power supply should be located as close to th...

Page 14: ...5 8 0 35mm 0 35mm 0 5mm 0 75mm 1 0mm 6 9 0 35mm 0 5mm 1 0mm 1 5mm 2 0mm 7 10 0 35mm 0 35mm 0 5mm 0 75mm 1 0mm V 11 Standard quality Medium quality Good quality Good quality High quality M 12 75 Coax...

Page 15: ...apartment speech in both directions video optional and lock release If the volume of speech needs to be adjusted this can be done by adjusting the presets on the rear of the amplifier at the door pane...

Page 16: ...PAGE 16 of 24 AUDIO VIDEO VANDAL RESISTANT TECHNICAL MANUAL VER1 1 ACCESSORIES CONNECTION GUIDE 3101 3101 3101...

Page 17: ...IDEO VANDAL RESISTANT TECHNICAL MANUAL VER1 1 WIRING DIAGRAM This diagram shows a single entrance vandal resistant door panel connected to two audio phones in the same apartment The lock release shown...

Page 18: ...VER1 1 WIRING DIAGRAM This diagram shows a single entrance vandal resistant door panel connected to multiple apartments The lock release shown is fail secure 12Vac We suggest running all telephones b...

Page 19: ...PAGE 19 of 24 AUDIO VIDEO VANDAL RESISTANT TECHNICAL MANUAL VER1 1 WIRING DIAGRAM This diagram shows a two entrance multiple apartments system 12Vac fail secure lock releases...

Page 20: ...PAGE 20 of 24 AUDIO VIDEO VANDAL RESISTANT TECHNICAL MANUAL VER1 1 WIRING DIAGRAM This diagram shows a single entrance VR video door panel connected to a single apartment with two videophones...

Page 21: ...PAGE 21 of 24 AUDIO VIDEO VANDAL RESISTANT TECHNICAL MANUAL VER1 1 WIRING DIAGRAM This diagram shows a two entrance system Two VR video door panels with two call buttons connected to two apartments...

Page 22: ...terminal 1 on the door panel amplifier for continuity back to terminal 1 on the telephone Before lifting the handset check the voltage to on terminal 1 of the amplifier is 8 12Vdc Trace this voltage t...

Page 23: ...with 12Vdc during a call Try taking the coax straight from the camera to a videophone Check for 20Vdc across the camera terminals I F1 during a call powered from Art890 Picture poor Check all end of l...

Page 24: ...curity Ltd Unit 4 7 Chillingham Ind Est Newcastle Upon Tyne NE6 2XX TEL 0870 300 1240 FAX 0191 224 5678 Southern Office 1 Osprey Trinity Park Trinity Way London E4 8TD FAX 0208 523 5825 TECHNICAL SUPP...