Two Wire Videokit ESVK Series
PrtCode:ESVK_ENG_1.3 – Pag.13/24
23/10/2008
Rev.1.3
PRIVACY UNLIMITED – SW2.1
If this switch is set to OFF (default), the privacy duration is defined from the switches 2 and 3 programming.If
this switch is set to ON, the privacy duration is unlimited and the service can be enabled or disabled only by
the relative button.
PRIVACY DURATION – SW2.2..3
This set up requires that the switch 1 is set to OFF.
2 3 Duration
OFF OFF 15
minutes
ON OFF 1
hour
OFF ON 4
hours
ON ON 8
hours
VIDEOMONITOR CONNECTION BOARD ART.5980
Fig.3
SIGNAL ON CONNECTION TERMINALS
Terminal Signal
Description
1 GND
Ground
2 BUS1
Bus input
3
4 BUS2
Bus input
5 S1
Terminal controlled by the
S1
button, close to
GND
until the button is pressed
6 LED
Auxiliary LED power supply input (12Vdc)
7 S2
Terminal controlled by the
S2
button, close to
GND
until the button is pressed
8 GND
Ground
9 GND
Ground
10 LB
Ingresso per chiamata di piano (attivo basso)
11 GND
Ground
12
13
14 +VAUX
Auxiliary power supply input (to be used when the switch 4 of SW2 is set to ON)
15
16
17
18 AL
Alarm input (not implemented yet)
19
20