Videx Alexadria DuraWand Portable Scanner User Manual Download Page 7

6

Uploading into Alexandria

 

If Alexandria is not already running start it up now.  To import the text file the Videx 

Downloader created enter the import command in the command line.  V3 users, enter “ *@” and 

press the enter key.  V5 users enter “*” and press the enter key.  This command brings up a 

file selection window.  If you saved your downloaded document to the default location which is 

the desktop then click the button on the right side of the window that says desktop.  Next scroll 

through the list of items on the desktop and double click the downloaded file.  This will start the 

upload into Alexandria.  The upload time depends on the size of the file.

Durawand Maintenance and Troubleshooting

DO NOT

      * Expose your DuraWand to temperatures in excess of 120 degrees F (for example a car dashboard 

on a sunny day, or any direct sunlight for extended periods.)

       * Allow the DuraWand to get wet.  Being caught occasionally in a light shower will probably not 

cause  problems  if  you  wipe  the  wand  off  promptly  and  allow  it  to  dry.    Avoid  immersion,  long-term 

exposure to high humidity, or regular exposure to rain.

IF YOU HAVE TROUBLE

       If you try to use your DuraWand and it does not sound a “good read” tone when you attempt to scan 

a bar code, one or more of the following things could be wrong:

       * The barcodes may be the wrong symbology.

       * An incorrect bar code symbology may be loaded.

       * The scan may be improperly performed.  While holding the scan button down, the scan should be 

made at a steady, moderately fast speed; the scan should start well within the white space preceding the 

code and should sweep completely through the bar code without going off the top or bottom.

       * The bar code contrast or printing quality may be inadequate.

       * The bar code may be smeared or otherwise unreadable.

       * The DuraWand batteries may be dead.

       * The batteries may be incorrectly installed.

       * The sapphire scan tip may be dirty.  Clean the scan tip with a soft cloth dampened with water.  A 

mild detergent and water solution may be used if necessary, but detergent residue should be removed 

with a clean damp swab.  Dry with a clean cloth.

       The  DuraWand  may  have  an  internal  component  malfunction.    If  you  know  you  are  using  valid 
bar codes and still cannot get your DuraWand to sound 

tone during a scan, you can determine what 

is wrong by using the following tests.

1. Attempt to transfer the scan data from your DuraWand to your computer using the Videx Downloader 

application.  If the DuraWand transfers the data, reprogram the DuraWand with the Videx Downloader 

application,  and  place  the  DuraWand  back  into  service.    If  the  DuraWand  does  not  transfer  the  data, 

go to Step 2.

Summary of Contents for Alexadria DuraWand Portable Scanner

Page 1: ...DuraWand Portable Scanner User s Guide For Macintosh...

Page 2: ...eries Alkaline batteries must not be recharged Remove a DuraWand with alkaline batteries from the Recharger Downloader Station immediately after programming and data transfer has been completed You ma...

Page 3: ...crew in a safe place to prevent loss 3 Remove the four old batteries and replace with four fresh AAA nickel cadmium batteries Be sure the batteries are installed correctly 4 Insert the key ring into t...

Page 4: ...Recharger Downloader Station should be lit Connection the RJ 11 plug of the serial cable to the Computer port of the Recharger Downloader Station and connect the other end of the cable to the modem o...

Page 5: ...d go to your apple menu control panels and choose Keyspan USA 28X Serial Assistant If the dirver has been installed and the adapter is connected to your computer you should see the following message i...

Page 6: ...on on where to save the file The recommended default location is to the desktop and the default name is videx COMPanion suggests downloading after every 200 barcode scans Therefore it is suggested tha...

Page 7: ...can a bar code one or more of the following things could be wrong The barcodes may be the wrong symbology An incorrect bar code symbology may be loaded The scan may be improperly performed While holdi...