66250870-EN - V2.1 - 30/11/16
7
Audiokit 8KC
Audiokit 8KC Series - Installation instructions
Art. 8800 - Art. 8800-3
Digital codelock module
DESCRIPTION
Access control system with 2 codes and 2 Relay outputs for
Art. 8800 (3 codes and 3 Relay outputs for Art. 8800-3).
• Engineer’s code to enter into the “Programming Menu” ( from
4 to 8 digits).
• Programming of the activation time of each relay from 1 up to
99 seconds or latching.
• Possibility to activate relay 1 by shorting terminal ”SW1” to
GND and relay 2 by shorting terminal “SW2” to GND. Both re-
lays will operate for the programmed time.
• Keypad gives an acoustic (buzzer) signal during the entering
of codes and a continuous melody for 4 or more seconds, ac-
cording to the number of mistakes (self protection).
• Keypad includes panel illumination and 2 LED’s to show the
following:
» Correct relay code (green LED on for 2 seconds).
» Red LED to indicate when in the “programming menu”.
MODELS
Art. 8800:
Module 2 Relay with keypad illumination LEDs
Art. 8800-3:
Module 3 Relay with keypad illumination LEDs
OPERATION
To use the system, type in the programmed code and press “ENTER”
, the green LED will illuminate and the relay will operate for the pro-
grammed time.To cancel remain open time, type in the same code
and press “CLEAR”. If a wrong code is entered, a continuous melody
will sound for 4 or more seconds, according to the number of mistakes.
INITIALIZATION
When the installation is concluded and carried out according
to the wiring diagram, power up the system and program it by
following the “VX8800 PROGRAMMING” Flow Chart.
PROGRAMMING
Refer also to flow chart.
• Enter “ENGINEER’S CODE”: first time type six times “1” (111111
factory preset) and press ENTER (The red LED will illuminate).
• Confirm “ENGINEER’S CODE” (typing again the same) or type
the new code (4 to 8 digits) then press ENTER (Melody). Press-
ing twice the ENTER button without changing the “ENGI-
NEER’S CODE”, will exit from the programming.
• Enter the code (4 to 8 digits) to enable “RELAY 1” (ACCESS 1) or
re-enter the existing code then press ENTER (Melody).
• Enter the “RELAY 1” operation time (2 digits 01 to 99 I.E. 05=5
seconds, 00= remain open time) or re-enter the existing time
then press ENTER (Melody).
• Enter the code (4 to 8 digits) to enable “RELAY 2” (ACCESS 2) or
re-enter theexisting code then press ENTER (Melody).
• Enter the “RELAY 2” operation time (2 digits 01 to 99 I.E. 05=5
seconds, 00=remain open time) or re-enter the existing time
then press ENTER (Melody).
• Enter the code (4 to 8 digits) to enable “RELAY 3” (ACCESS 3
only for Art. 8800-3) or re-enter the existing code then press
ENTER (Melody).
• Enter the “RELAY 3” (only for Art. 8800-3) operation time (2
digits 01 to 99 I.E. 05=5 seconds, 00=remain open time) or
re-enter the existing time then press ENTER (Melody).
• The system is ready to use (the red LED will be off).
Fig. 1
ENTER THE
"ENGINEER’S CODE"
CONFIRM
OR CHANGE
"ENGINEER’S CODE"
ENTER
"ACCESS 1 CODE"
ENTER
"ACCESS 2 CODE"
ENTER
"ACCESS 3 CODE"
***
ENTER
"ACCESS 1 TIME"
ENTER
"ACCESS 2 TIME"
ENTER
"ACCESS 3 TIME"
***
SYSTEM
READY TO USE
First time six times
1 “111111” factory
preset
Type again six times
“1” or the new en-
gineer’s code 4 to 8
digits
Code to enable relay 1
4 to 8 digits
Code to enable relay 2
4 to 8 digits
Code to enable relay 3
4 to 8 digits
Two digits (01 to 99)
i.E. 05=5 Seconds
00= remain open
Two digits (01 to 99)
i.E. 05=5 Seconds
Two digits (01 to 99)
i.E. 05=5 Seconds
Red led will be off
Press Enter
(Red LED will
be ON)
Press Enter
(melody)
Press Enter
(melody)
Press Enter
(melody)
Press Enter
(melody)
Press Enter
(melody)
Press Enter
(melody)
Press Enter
(melody)
*** Only for Art. 8800-3