66550032-EN - V6.2 - 31/10/20
- 28 -
ESVK/6286 Series “2 wire Bus” videokit
ESVK/6286 Series - Installation handbook
Art.
2321-2321/P
Power supplies
65
157,5
105
Art.2321
0V
230V
+
_
BUS
Fig. 1
Fig. 2
DESCRIPTION
These two power supplies are speci
fi
cally designed for VX2300 digital system.
The Art.
2321 can be used for systems with 1 entrance up to 20 users.
Art.
2321/P is for systems with more than 1 entrance and up to 40 users.
For more than 40 users it is necessary to add a Art.
2321/P to the BUS.
CONNECTION TERMINALS AND JUMPERS
0
Mains input
~230V
BUS +
BUS terminals
BUS
–
BUS +
BUS terminals (only Art.
2321/P)
BUS
–
V1
Jumper to adjust the output voltage (only Art.
2321/P).
V1=Low, V2=Medium, V3=Maximum. Set to maximum
(V3) when the unit is used together with Art.
2301N,
otherwise leave in a low or medium position.
V2
V3
CONNECTION TO MAINS
WARNING!
The system must be installed only by a quali
fi
ed eletrician
and in accordance with national rules in force and installa-
tion diagrams (if provided).
In particular we recommend that:
The system is connected to the mains through an all-pole
circuit breaker which has a contact separation of at least
3mm in each pole and shall connect all poles simultaneously;
The all-pole circuit breaker shall be placed for ease of ac-
cess and the switch shall remain readily operable.
Only for indoor use in dry places. Do not execed the maxi-
mum power load indicated.
MOUNTING INSTRUCTIONS
Fig. 3
1
2
Fig. 4
Fig. 5
Fig. 6
1. Remove the terminal side covers by unscrewing the retaining screws (
2. Fix the power supply to a DIN rail (
) or directly to the wall using two expansion type screws (
3. Isolate the mains using the circuit breaker mentioned above then make the connections as shown on the installation diagrams (if provided);
4. Check all connections and secure the wires into the terminals;
5. When all connections are made replace and
fi
x the terminal covers with the relevant screws (
);
6. Restore the mains.
SPECIFICATION
Housing/Mounting:
9 Module A Type DIN box (Art.
2321) –
12 Module A Type DIN box (Art.
2321/P)
/ DIN Bar or directly to the wall
Controls:
Voltage ampli
fi
cation (3 levels)
Power Supply:
230 Vac
Working Temperature:
-10 +50°C
ART.
2321
-
ELECTRICAL DATA
Mains voltage:
230 Vac ~ 50/60 Hz
Output voltage:
32 Vdc 0.8 A
Internal fuse:
-
ART.
2321/P
-
ELECTRICAL DATA
Mains voltage:
230 Vac ~ 50/60 Hz
Output voltage:
35 Vdc 1.5 A
Internal fuse:
T 350 mA L 250