66550032-EN - V6.2 - 31/10/20
- 25 -
ESVK/6286 Series “2 wire Bus” videokit
ESVK/6286 Series - Installation handbook
Art.
6286
3.5" colour display videophone
VIDEOPHONE ADDRESS
–
SW1.1..7
The table below shows how to set the address of the videophone. Considering that ON = 1 and OFF = 0, multiply
each digit for the relevant decimal weight then sum values obtained to get the address:
E.g.
as highlighted in
the table OFF, ON, OFF, OFF, ON, OFF, ON in binary is equal to 0100101 then multiplying each digit for the rele-
vant decimal weight you obtain the address that is 37.
SWITCHES STATUS
BINARY CODE
-
DECIMAL WEIGHT
ADDRESS
7
6
5
4
3
2
1
64
32
16
8
4
2
1
OFF
OFF
OFF
OFF
OFF
OFF
ON
0
0
0
0
0
0
1
1
OFF
OFF
OFF
OFF
OFF
ON
OFF
0
0
0
0
0
1
0
2
OFF
OFF
OFF
OFF
OFF
ON
ON
0
0
0
0
0
1
1
3
OFF
OFF
OFF
OFF
ON
OFF
OFF
0
0
0
0
1
0
0
4
OFF
ON
OFF
OFF
ON
OFF
ON
0
1
0
0
1
0
1
37
ON
ON
ON
ON
ON
ON
ON
1
1
1
1
1
1
1
127
Note:
The maximum number of units allowed is 100 but the address of each unit can be a value between 1 and 127.
VIDEOPHONE END OF LINE TERMIANTION
–
SWCH1
Looking at the videophone from the rear:
SW
Move the switch to the right position to enable the bus termination
6
7
8
1
2
3
5
4
ON
SW1
6
7
8
2
3
5
4
ON
SW
Move the switch to the left position to disable the bus termination
In case of more units (intercoms, videophones or video monitors) in a parallel connection (bus wires are connected to the terminals
of the
fi
rst unit then from this to the second and so on up to 4 units max) the BUS termination must be enabled only for the last unit
in the chain while on all other units it must be set to disabled.
INTERCOMMUNICATION MODE
–
SW3.1
This switch establishes the intercommunication mode: in OFF position (default) intercommunication is between units in
the same apartment (same addresses but di
ff
erent extension); in ON position the intercommunication is between units
in di
ff
erent apartments (di
ff
erent addresses).
On installations where there are more than one intercom/videophone in the same apartment and intercommuni-
cation between di
ff
erent apartments is required, only one intercom/videophone may be set with this function (SW3.1=ON,
SW3.2=OFF, SW3.3=OFF). The other intercom/videophones in the apartment must be set for local intercommunication with
extension addresses “2-4” (slaves). From the intercom/videophone set for intercommunication with other apartments it
will not be possible to intercommunicate within the apartment but slave extensions 2-4 will be able to intercommunicate
with each other within the apartment.
EXTENSION NO
–
SW.3.2..3
If the intercommunication between apartments is enabled (switch 1 of
SW3
= ON)
leave these two switches in default position (both to OFF). Otherwise, if the in-
tercommunication is between the same apartment (switch 1 of
SW3
= OFF), set
the extension addresses starting always from 1. During the external call, all video
monitors in the same
fl
at will ring but the video will be shown only from the vide-
ophone with extension address 1.
SLAVE MODE
-
SW3.4
This set up concerns the answering mode of the video monitor when there is more than one unit (max 4) in the same
apartment. OFF (default) = during a call, only the video monitor with extension 1 (master) will show the video. ON =
the video monitor will be switched on independently of the extension address: in this case the video monitor must be
supplied locally using a power supply Art.
2321 or Art.
AMR-12, see notes on
12M
and
VA
on “Connection Terminals
Signals” table (the local power supply is required for each black & white slave videophone or starting from the third slave
videophone when they are all colour videophones).
If you set for one slave videophone, you must set ON the same switch also for the relevant master videophone.
ON
1 2 3 4 5 6 7
8
SW1.1..7
ON
1
2 3 4
SW3.1
ON
1
2 3
4
SW3.2..3
2
3
EXTENSION NO.
OFF OFF 1 (default, master)
ON
OFF 2 (slave)
OFF
ON 3 (slave)
ON
ON 4 (slave)
ON
1 2 3
4
SW3.4