Videx 4838 Series Installation Instruction Download Page 2

 

Rev.1.4 

19/09/2012 

PrtCode:66250240.doc

FRONT LEDS – SIGNALLING DESCRIPTION 
 

Sign Description 

 

When illuminated, indicates that it is not possible to make a 
call because a call or a conversation is in progress (from 
the outdoor station from which you are calling or from 
another outdoor station on systems with multiple 
entrances). The LED will be off when the system is in 
stand-by 

 

If illuminated, indicates that the call from the outdoor station 
is in progress. The LED will switch OFF when the call is 
answered or after the programmed number of rings. 

 

If illuminated, indicates that it is possible to speak because 
the call has been answered. The LED will switch OFF at the 
end of a conversation (or at the end of the conversation 
time). 
 

 

If illuminated, indicates that the door lock has been 
operated. It will switch OFF at the end of the programmed 
“door opening” time. 

 
 
 
 
TERMINALS: 

Speech in (toward the speaker) 

Speech out (from the microphone) 

+12 

+12Vdc power input 

GND 

Ground 

Door Open command (input active low)) 

PTE 

Local Door open command (input active low)) 

Relay - common contact 

NC 

Relay - normally closed contact 

NO 

Relay - normally open contact 

BSY 

Busy signal (input/output active low) 

SL 

Video power supply and/or exchanger enabling signal (output 
active low) 

F1 

Camera enabling signal (output active low) 

LB 

Local bell electronic call tone (output square wave 12Vpp) 
 

Main call tone (output square wave 12Vpp) 

CB 

Enabling signal for intercoms with privacy of speech (for “5+1” 
systems. 

COM 

Push button common 

P1 

Output call button 1 (available on all versions except -0

P2 

Output call button 2 (available only on -2 and -2D versions) 

P3 

Output call button 3 (available only on -1D and -2D versions) 

P4 

Output call button 4 (available only on -2D version) 

 

LED FRONTALI – DESCRIZIONE INDICAZIONI 

 

Simbolo Descrizione 

 

Se acceso, indica che non è possibile chiamare a causa di 
una chiamata o conversazione in corso, dal posto esterno 
in uso o da un altro posto esterno in caso di sistemi a più 
ingressi. Il LED si spegne con l’impianto a riposo (nessuna 
conversazione o chiamata in corso). 

 

Se acceso, indica che è in corso la chiamata dal posto 
esterno che si sta utilizzando. Il LED si spegne alla 
risposta dell’utente chiamato o al raggiungimento del 
numero di squilli programmati. 

 

Se acceso, indica che l’utente chiamato ha risposto e la 
conversazione può avere inizio. Il LED si spegne al termine 
della conversazione (l’utente chiamato riaggancia la 
cornetta) o allo scadere del “tempo di conversazione” 
programmato. 

 

Se acceso, indica che l’utente chiamato ha aperto la porta. 
Il LED resta acceso per tutto il “tempo d’apertura porta” 
programmato. 

 
 
 
 

MORSETTIERA: 

Audio in (verso lo speaker del portiere) 

Audio out (dal microfono del portiere) 

+12 

Ingresso d’aliment12Vdc 

GND 

Massa 

Comando “apri-porta” (input attivo basso) 

PTE 

Comando “apri-porta” locale (input attivo basso) 

Relé - contatto comune 

NC 

Relé - contato normalmente chiuso 

NO 

Relé - contatto normalmente aperto 

BSY 

Segnale d’occupato (input/output attivo basso) 

SL 

Segnale d’abilitazione alimentatore video e/o scambiatore 
(output attivo basso) 

F1 

Abilitazione telecamera (output attivo basso) 

LB 

Nota elettronica per campanello di piano (output onda quadra 
12Vpp) 

Nota elettronica di chiamata (output onda quadra 12Vpp) 

CB 

Segnale d’abilitazione citofoni con segreto di conversazione 
(sistemi “5+1” output 12Vdc) 

COM 

Comune pulsanti 

P1 

Uscita pulsante 1 (disponibile in tutte le versioni eccetto -0) 

P2 

Uscita pulsante 2 (disponibile solo nelle versioni -2 e -2D) 

P3 

Uscita pulsante 3 (disponibile solo nelle versioni -1D e -2D) 

P4 

Uscita pulsante 4 (disponibile solo nella versione -2D) 

 

 

 

BUTTON LAYOUT 

ORDINE PULSANTI 

 

 

 

 

Art.4838-1 Art.4838-2 Art.4838-1D 

Art.4838-2D 

 
 
 
 

 

TECHNICAL SPECIFICATION 
Power Supply: 

 

12Vdc 

Power Consumption: 

Approx. 25mA - stand-by 

 

 

 

Approx. 150mA - during a call 

 

 

 

Approx. 70mA - during a conversation 

Working Temperature: 

-10 +50 C 

SPECIFICHE TECNICHE 

Tensione d’alimentazione: 

12Vdc 

Assorbimento: 

 

circa 70mA in stand-by 

 

 

 

circa 200mA durante la chiamata 

 

 

 

circa 100mA durante la conversazione 

Temperatura di lavoro: 

-10 +50 C 

 

CUSTOMER SUPPORT INFORMATION 

INFORMAZIONI ASSISTENZA CLIENTI 

All Countries Customers 

UK Customers 

Clienti di tutti i Paesi 

Clienti UK 

VIDEX Electronics S.p.A. 

www.videx.it

 – 

[email protected]

 

Tel.+39 0734 631669 
Fax +39 0734 632475 

VIDEX Security LTD 

www.videx-security.com

 

Tech Line 0191 224 3174 
Fax 0191 224 1559 

VIDEX Electronics S.p.A. 

www.videx.it

 – 

[email protected]

 

Tel.+39 0734 631669 
Fax +39 0734 632475 

VIDEX Security LTD 

www.videx-security.com

 

Tech Line 0191 224 3174 
Fax 0191 224 1559 

 
 

 

The product is CE marked demonstrating its conformity and  is for distribution within all 
member states of the EU with no restrictions. 
This product follows the provisions of the European Directives  
89/336/EEC & 92/31/EEC (EMC),  
73/23/EEC (LVD) and 93/68/EEC (CE marking). 

Il prodotto è marchiato CE a dimostrazione della sua conformità e può essere distribuito 
liberamente all’interno dei paesi membri dell’unione europea EU. 
Questo prodotto è conforme alle direttive Europee 
89/336/EEC & 92/31/EEC (EMC), 
73/23/EEC (LVD) e 93/68/EEC (Marcatura CE). 

Reviews: