66250203 - V4.4 - 15/05/22
- 16 -
4000 Series Vandal Resistant Range
Art. 4212 - Installation instructions
Surface mounting door station installation
A
B
C
C
Fig. 1
B
Fig. 2
B
F
D
D
E
G
G
E
Fig. 3
Fig. 4
B
C
A
C
Fig. 5
1. To separate the panel
A
from the surface box
B
, first remove the two screws
C
located on the bottom of the surface box using
a screwdriver, then lever the panel from the bottom to extract it
;
2. Place the surface box
B
against the wall (165-170cm between the top of the box and the floor lever) and mark the 4 fixing holes
for the wall plugs and the hole for the cables
;
3. Drill the 4 fixing holes
D
, insert the wall plugs
E
and feed the cables
F
through the surface box, fix surface box to the wall using
the screws
G
;
4. Connect the wires using a terminal screw driver then setup the dip-switches as per provided connection diagram or instruction
sheet, then power up the system and check that it works correctly
;
5. Insert the top end of the panel
A
first, then level down and fix to the surface box
B
with the two screws
C
.
Do not over tighten the screws more than necessary.
Summary of Contents for 4000 Series
Page 33: ...66250203 V4 4 15 05 22 33 ...
Page 34: ...66250203 V4 4 15 05 22 34 ...