66250203 - V4.4 - 15/05/22
- 15 -
4000 Series Vandal Resistant Range
Art. 4212 - Installation instructions
Flush mounting door station installation
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
1. Embed the flush mounting box into the wall (160-170 cm between the top of the box and the floor level as shown in
) pass-
ing the cables (
Fig. 2
) through a cable knockout hole in the box;
2. Make all the connections on the removable terminal blocks
, then plug back into the panel
setup the dip-switches
as per provided connection diagram or instruction sheet, then power up the system and check that it works correctly;
In order to prevent water ingress we highly recommend using a silicon sealant between the plate and the wall ON
THE LEFT, TOP AND RIGHT SIDES ONLY. DON’T USE SILICON SEALANT ON THE BOTTOM SIDE OF THE PLATE (Fig. 4);
3. Fix the plate to the flush mounting box using the screwdriver provided (torx end) and the pin machine torx screws (
).
Do not over tighten the screws more than necessary.
Summary of Contents for 4000 Series
Page 33: ...66250203 V4 4 15 05 22 33 ...
Page 34: ...66250203 V4 4 15 05 22 34 ...