background image

66251830 - V1.2 - 30/04/21

- 2 -

IP system - Accessories

Art. 2505 

 - Installation instructions

Art. 2505

 2 inputs- 2 outpus IP relay module

PROGRAMMING

All programming is carried out through the Videx IP Wizard software.

On the lower side of the device there is a QR code with MAC ad-

dress and the various parameters.

To download the programming software 

VX IP Wizard

 and obtain the latest firmware 

and manuals please visit the following web-

site and register

https://service.videx.it/

TECHNICAL SPECIFICATION

Power supply:

 

12Vdc or POE

Power consumption:

  Stand-by: 100mA

Operating: 100mA

Working temperature:

 

-20 +60° C

MOBILE CONNECTION TERMINALS SIGNALS

+12

12Vdc 400mA power supply input

GND

NO1

Relay 1 normally open contact

Max 12-24 

Vac/dc 0.4A

NC1

Relay 1 normally closed contact

C1

Relay 1 common contact

NO2

Relay 2 normally open contact

Max 12-24 

Vac/dc 0.4A

NC2

Relay 2 normally closed contact

C2

Relay 2 common contact

IN1

Active low input 1 (when enabled activate the relay 1)

IN2

Active low input 2 (when enabled activate the relay 2)

GNDI

Ground

A

RS-485 Connection

(termination adjusted through the 

I

 switch)

B

GND

Summary of Contents for 2505

Page 1: ...r a input is energized P1 AND P2 BUTTONS MANUAL ACTIVATION OF RELAYS P1 and P2 buttons Fig 1 D and F are used for manually ac tivate a relay If the relay activates for a specific time it will remain actived for the specified time If the relay operates in latch mode it will enable and disable every time the button is pressed P3 BUTTON BOOTLOADER MODE P3 button Fig 1 H is used to start the bootloade...

Page 2: ...vice videx it TECHNICAL SPECIFICATION Power supply 12Vdc or POE Power consumption Stand by 100mA Operating 100mA Working temperature 20 60 C MOBILE CONNECTION TERMINALS SIGNALS 12 12Vdc 400mA power supply input GND NO1 Relay 1 normally open contact Max 12 24 Vac dc 0 4A NC1 Relay 1 normally closed contact C1 Relay 1 common contact NO2 Relay 2 normally open contact Max 12 24 Vac dc 0 4A NC2 Relay 2...

Page 3: ...IVAZIONE MANUALE DEI RELÈ I pulsanti P1 e P2 Fig 1 D e F vengono utilizzati per l attiva zione manuale dei relè Se il relè è impostato per un tempo determinato rimarrà attivo per il tempo specificato Se il relè opera in modalità latch verrà abilitato e disabilitato ad ogni pressione del pulsante PULSANTE P3 MODALITÀ BOOTLOADER Il pulsante P3 Fig 1 H viene utilizzato per avvialre la modalità bootlo...

Page 4: ...web https service videx it SPECIFICHE TECNICHE Alimentazione 12Vdc o POE Assorbimento Stand by 100mA In funzione 100mA Temperatura di lavoro 20 60 C SEGNALI MORSETTI DI CONNESSIONE MOBILI 12 Ingresso alimentazione 12Vdc 400mA GND NO1 Relè 1 contatto normalmente aperto Max 12 24 Vac dc 0 4A NC1 Relè 1 contatto normalmente chiuso C1 Relè 1 contatto comune NO2 Relè 2 contatto normalmente aperto Max 1...

Page 5: ...s IPure diagram 002 EN V1 0 15 04 21 Videx Electronics S p A www videx it 2 2 2 2505 Electric lock 6798 LAN LAN LAN PoE switch router 2505 Gate Relay 1 Relay 2 4533X 2 HDR 15 12 Doors and gates activation through a relay which is separate from the outdoor station Attivazione automazioni tramite relé scorporato dal posto esterno Doors and gates activation through long distance remote buttons Attiva...

Page 6: ...N LAN LAN PoE switch router World Wide Web 2505 Smartphone with CloudNected app 2505 Smartphone with CloudNected app 2505 Smartphone with CloudNected app Electric lock Gate 4533X 2 plus 4045 HDR 15 12 6398 6798 6296 Art 2505 CloudBox mode Art 2505 modalità CloudBox ...

Page 7: ...ion et évite les éventuels effets négatifs sur l environnement et la santé humaine en raison de la présence possible de substances dangereuses dans ceux ci ELIMINACIÓN De conformidad con el Decreto legislativo n 49 de 14 de marzo 2014 Aplicación de la Directiva 2012 19 UE relativa a resi duos de aparatos eléctricos y electrónicos RAEE El símbolo del contenedor tachado indicado sobre los aparatos o...

Page 8: ...trictions This product follows the provi sionsoftheEuropeanDirectives2014 30 EU EMC 2014 35 EU LVD 2011 65 EU RoHS CE marking 93 68 EEC IlprodottoèmarchiatoCEadimostrazionedellasuaconformitàepuòesseredistri buito liberamente all interno dei paesi membri dell Unione Europea UE QuestoprodottoèconformealledirettiveEuropee 2014 30 UE EMC 2014 35 UE LVD 2011 65 UE RoHS marcatura CE 93 68 EEC Leproduite...