66251830 - V1.2 - 30/04/21
- 2 -
IP system - Accessories
Art. 2505
- Installation instructions
Art. 2505
2 inputs- 2 outpus IP relay module
PROGRAMMING
All programming is carried out through the Videx IP Wizard software.
On the lower side of the device there is a QR code with MAC ad-
dress and the various parameters.
To download the programming software
VX IP Wizard
and obtain the latest firmware
and manuals please visit the following web-
site and register
https://service.videx.it/
TECHNICAL SPECIFICATION
Power supply:
12Vdc or POE
Power consumption:
Stand-by: 100mA
Operating: 100mA
Working temperature:
-20 +60° C
MOBILE CONNECTION TERMINALS SIGNALS
+12
12Vdc 400mA power supply input
GND
NO1
Relay 1 normally open contact
Max 12-24
Vac/dc 0.4A
NC1
Relay 1 normally closed contact
C1
Relay 1 common contact
NO2
Relay 2 normally open contact
Max 12-24
Vac/dc 0.4A
NC2
Relay 2 normally closed contact
C2
Relay 2 common contact
IN1
Active low input 1 (when enabled activate the relay 1)
IN2
Active low input 2 (when enabled activate the relay 2)
GNDI
Ground
A
RS-485 Connection
(termination adjusted through the
I
switch)
B
GND