background image

 

STATE

PWR

RESET

AIN

AOUT

SD CARD

LAN

DC 12V

ALARM 485

COM NO INGND

+

-

 

1. 

Power Interface( DC 12V )

: Connect with power adaptor.   

2. 

Network Interface( LAN  )

: Ethernet port for 10/100M. Through this port, you can connect  the 

camera with other network devices like switcher, hub, router, etc. 

3. 

Reset Button (RESET)

: Long press this button for more than 30 seconds when power on, the camera will 

recover to default configuration. Default IP address is 

192.168.1.88

, user name “

admin

” and password “

admin

”. 

4. 

Alarm Interface (COM, NO, IN, GND)

: connect with external alarm input & output devices. See 

below detailed information. 

A L A R M

485

COM NO INGND

+

-

 

5. 

RS485 Interface: 

Supports standard 485 PTZ protocols, for connecting with PTZ. Please see above picture.   

6. 

Audio input (AIN) 

:  connects with external voice collectors like microphone to realize voice 

collection function.

 

7. 

Audio output (AOUT)

: connects with external play devices like act loudspeaker to realize broadcast function. 

8. 

SD card slot:

 Supports SD card local storage for video recording and snap, up to 64G(Optional). 

9. 

Indicator (PWR, STATE)

: When the camera is in power on, PWR light will go on. When insert SD 

card, STATE light will go on. 

 

For the first network connection, please follow the following steps to configure your network.   

1. Use cable to connect camera with computer. 

2. When connecting  with 10M network, the orange indicator will be on, when connecting  with 100M 

network, the green indicator will also be on. 

3. If your computer IP address is in different gateway with that of camera, please change your computer 

IP address in the same gateway as camera, for example, 192.168.1.87. 

4. In the IE browser, please input camera IP address (default IP “

192.168.1.88

”) and enter, then below 

dialog table will come out. 

      

        

 

              Picture 1                                Picture 2     

5. After input the user name and password (default user name “

admin

” and password “

admin

”), below 

activeX controls will show in the screen. This is a prerequisite activeX and controls for this application, 

without any danger information. Please run it according to above picture 2.   

6. After finish the activeX and controls installation, please refresh the web page and below picture will 

come out.   

 

7. If you want to change the camera IP address, please refer to the user manual. 

 

Note

: Please adjust the IP address well first and then install the camera. 

Chapter 4: Network connection

 

 

Chapter 3: Introduction on cable interface

 

 

 

www.VideoTrack.us

www.VideoTrack.us

Reviews: