EN - English - I
nstruc
tion manual
12
MNVCMBA_1817_EN
7.3.5 Products connection to the 24Vac
power supply line
Earth cable should be about 10mm longer
than the other two, so that it will not be
disconnected accidentally if pulled.
Check the requirements of the related VIDEOTEC
products (Tab. 5, page 14).
From the connectors’ board, take out the removable
male connectors J6, J7 and connect the 24Vac power
supply cables of the devices following the polarity
indicated on the screen printing (7.3.3 Connector
CONNECTION OF THE 24VAC OUTPUT POWER SUPPLY LINE
Colour
Terminals
Power supply 24Vac
Defined by the installer
~
Defined by the installer
~
Yellow/Green
Tab.
3
7.3.6 Multi-polar connectors (relays,
alarms, serial line)
Consult the installation manuals of the devices to
connect for specifications on relays, alarms and
serial line. Use the multi-polar connectors, on the
connectors’ board, to transfer signals from the devices
to the main system considering the connector J24,
replica J25 and J10 replica J11 (7.3.3 Connector board
7.3.7 BNC connectors (analogue video)
Consult the installation manuals of the devices to
connect for specifications on analogue video signals.
Use the BNC connectors, on the connectors’ board, to
transfer signals from the devices to the main system
considering the connector J22, replica J23 and J26
replica J27 (7.3.3 Connector board description, page
7.3.8 Connectors for the wash system
Consult the installation manuals of the wash system
to connect for the relevant specifications. Connect
the contacts of the command relay of PTZ or the
cameras and the power supply cables (24Vac) of the
wash system to the connectors J8 and J9 following
the screen printing on the board (7.3.3 Connector
L
J8
N
RL
Solenoid valve,
Videotec washing
system (WASEX)
Videotec PTZ
Fig.
4