Vi-Q4/C3
User Manual
Viq602c
Command
Name
Command
Originator
CC
PP
Description
ASCII string in the extended data XX..XX.
Request
temperature
EXT
0x43 0xE5 Issuing this command to the VP results in a Temperature
reply command
Temperature
VP
0x44 0xE5 This reply command from the VP includes the Temperature
ASCII string in the extended data XX..XX. Temperature is
degrees Celsius.
Request
Firmware
Revision
EXT
0x43 0x31
Issuing this command to the VP results in a Firmware reply
command
Firmware
Revision
VP
0x44 0x31
This reply command from the VP includes the firmware
revision ASCII string in the extended data XX..XX.
Set current
format
EXT
0x42 0xE6 Set the currently displayed format. A single extended data
byte XX selects the required format number 0x01 to 0x20
Set “Normal”
format
EXT
0x42 0xE7 Set the format that is selected when in “Normal” state. A
single extended data byte XX selects the required format
number 0x01 to 0x20
Set “Reversed”
format
EXT
0x42 0xE8 Set the format that is selected when in “Reversed” state. A
single extended data byte XX selects the required format
number 0x01 to 0x20
Set Normal or
Reversed state
EXT
0x42 0xE9 Set “Normal” or “Reversed” state. A single extended data byte
XX 0x00 for Normal and 0x01 for reversed.
Query current
format
EXT
0x43 0xE6 Issuing this command to the VP results in a Current Format
reply command
Query
“Normal”
format
EXT
0x43 0xE7 Issuing this command to the VP results in a Normal Format
reply command
Query
“Reversed”
format
EXT
0x43 0xE8 Issuing this command to the VP results in a Reversed Format
reply command
Query Normal
or Reversed
state
EXT
0x43 0xE9 Issuing this command to the VP results in a Normal or
Reversed State reply command
Query Menu
Mode
EXT
0x43 0xEA Issuing this command to the VP results in a Menu Mode reply
command
Current format VP
0x44 0xE6 VP reports the current format. A single extended data byte XX
identifies the format number 0x01 to 0x20
“Normal”
format
VP
0x44 0xE7 VP reports the “Normal” format. A single extended data byte
XX identifies the format number 0x01 to 0x20
Reversed”
format
VP
0x44 0xE8 VP reports the “Reversed” format. A single extended data
byte XX identifies the format number 0x01 to 0x20
Normal or
Reversed state
VP
0x44 0xE9 VP reports the state. A single extended data byte XX
identifies the “Normal” state as 0x00 or reversed state as
Videoswitch Ltd
17/26
07/09/15