Normal Operation 

 
Making a Call from a Entrance Station to a Handset 

The system is ready to use when the Entrance Station displays   

  on it’s LEDs. 

To make a call , enter the related 4 digit unit No. For example; 

Unit No. 7   

Æ

 0007 

Unit No. 70 

Æ

 0070

 

If an error is made when entering the No. press 

 key   to clear the entry. 

Following the 4  digit entry, the Entrance Station extends the call automatically; in this phase, 
the melody sounds on both Entrance Station for approximately 30 sec. and the Video Handset 
for approximately 5 seconds if not answered. Video screen of Handsets will be on 
approximately 30 seconds and display the image from the Entrance Station camera.  
If the Handset of the unit called is in use or does not exist, a series of short beep for 7 seconds 
will be heard as an error message. 
 

 
Making a Call from a Entrance Station to the Guard Station 

Press ‘#’ button to call guard. 
If the guard station is in use or does not exist, a series of short beep for 5 seconds will be heard 
as busy tone.

 

 

 
Door opening by the password at the Entrance Station (Optional Extra) 

Door can be opened by pressing “

” and a 4-digit password. 

 
 

Door opening from the Handsets 

During the conversation, the electric door can be activated by pressing the 

 

 

 button  on the 

handset. A melody will be heard to indicate opening the door on handset. The Entrance Station 

displays 

 during the door open. 

 

Monitoring Entrance area 

By pressing 

 

 button without lifting hand-piece, images from each Entrance Stations

 

can be 

display on the screen one after the other. The monitor will be turned off 30 second later 
automatically or can be turned off manually by picking up and hanging up the hand piece. 

 
The second call 

Thanks to multi-audio channel capability, one Video/Audio and up to 7 audio conversations (in 
Standard System 1 additional audio conversations) can be made on a system simultaneously. 
(The second call and voice conversation from different Entrance station to different Handset can 
be made even if someone uses the system.) Please note there will be no image on the Video 
Handset screen for the second call. 

 
Line Busy condition

 

When all of audio channels are engaged, a series of short beep for 5 seconds will be heard as 
busy tone. 

With Guard Station (TVG-700 / TAG-700)
Making and answering a Panic Call to the Guard Station (caretaker station) 

Press the 

 

 button on handset for 2 seconds. Press again to mute beeping 

noise. 
For example, if a panic call is made from Unit 101 then 

  

ÅÆ

 

 will be displayed on the Display Unit with a loud alarm sound. 

 

Making a call from the Guard station to a Handset 

Pick up the hand piece and press unit No in 4 digit. 
A melody will be heard if the call is made properly. 
 

Making a call from Handsets to Guard Station  

Pick up the hand piece from the handset and press 

 

 button. A melody will be 

heard if the call is made properly. If the guard station is in use or does not exist, a 
series of short beep for 5 seconds will be heard as a busy tone.  
 

Connection a call from a Handset to another Handset through the Guard Station 

During conversation with a Handset, press Hook Switch on Guard Handset for 0.5 
sec and enter associated unit No. than hang up (Optional Extra). 

Operating the Message Indicators from the Guard Station   

 

 

Guard can make the Message Indicator of Handsets to blink to inform the resident 
that the  
guard has a message. 
To blink the Message Indicator, press “

” then 4 digit Unit No. then hang up. 

To cancel it, press “#” then 4 digit Unit No. then hang up. 
 
 

    

 

TMN-700 Video Handset 

 

 button   : Monitor/Key 

                        Press to open associated door. 
                        Press to display entrances on monitor. 
                        Pick  up  the  handset  and  press  it  to  call 
Guard 

 

 button  : Panic  

                        Press 2 Seconds to call Guard Station 

 

 LED     : Message Indicator 

                        Normally Off, Blinks when guard has a  
                        Message. Automatically off when call the  
                        Guard  station  by  picking  up  the  hand 
piece. 

Summary of Contents for Digital 700

Page 1: ...tiple Riser Port 1 2 3 4 5 6 7 8 9 0 VIDEOMAN SYSTEMS Co V 3 0 21 9 01 VIDEOMAN Systems Co Unit 13 112 Benaroon Rd BELMORE NSW 2192 AUSTRALIA Phone 02 9758 9509 Fax 02 9758 9510 e mail info videoman c...

Page 2: ...4 5 Mounting Entrance Station 6 General Wiring Guide 7 Wiring Requirement Single Riser Configuration 8 Wiring Requirement Multiple Riser Configuration 9 Connection Diagram 10 11 System Programming 12...

Page 3: ...roperly Which eliminates huge time and effort in rectifying the problem Connectors for all necessary connection no screws Programmable lift controller Each unit has its own level No in programming pro...

Page 4: ...al audio conversations can be made on a system simultaneously The second call and voice conversation from different Entrance station to different Handset can be made even if someone uses the system Pl...

Page 5: ...ore N A Between Main controller Decoder 0 44 mm 2 7core shielded 1 5 mm 2 2core 0 44 mm 2 6core shielded RG59 Coax 1 5 mm 2 2core Between Decoder Handset 0 44 mm 2 5core shielded 0 44 mm 2 3core shiel...

Page 6: ...A Ver 1 1 Pjt No t5s4v2 Eos Australia P L Date 15 09 01 A B E A 7 core 14 020 Shielded Cable 0 44mm2 B 2 core 14 020 Cable 0 44mm2 C 3 Core 14 020 Shielded Cable 0 44mm2 D 5 Core 14 020 Shielded Cable...

Page 7: ...5 4 3 2 1 1st 16th Floor DC PowerJack TVE700 TVE700 Video Entrance Station DOOR LATCH DOOR LATCH TVG700 Video Guard Station TLC700 Lift Controller TDS700 Display Unit TMN700 Video handset Power Exit P...

Page 8: ...minutes c Main Controller ID No 00 49 When there is only one Main controller enter 00 by pressing key Please skip this step if there is no Master Station by pressing key Enter associated 4 digit No ex...

Page 9: ...ept existing Level No The first two digit must be 06 12 Repeat step 8 9 10 for next unit Depending on the physical port socket location in the system c Socket No on Decoder 0 9 d Decoder No on the Sys...

Page 10: ...S Port on the Main Controller 1 2 3 4 5 6 7 8 9 0 TVE 700 Video Entrance Station button Reset Door open password entry mode button Guard Call Microphone Adj Speaker Volume Adjustment N B Door Lock con...

Page 11: ...guard station Dimension 107mm W x 218mm H x 70mm D TPS 24 Power Supply 24V DC 2 0Amp SMPS power supply Dimension 84mm W x 146mm H x 48mm D Special Extras Long distance interface unit for the Guard Sta...

Page 12: ...06 9 06 0 06 0 06 1 06 1 06 2 06 2 06 3 06 3 06 4 06 4 06 5 06 5 06 6 06 6 06 7 06 7 06 8 06 8 06 9 06 9 06 Hard No Decoder Socket No Hard No Decoder Socket No Riser No 0 5 Dec No 0 49 Plug No Soft No...

Reviews: