g) Get the status of zoom position

:RFC9100

If echo back data is not “FF”, zoom position
is calculated by following equation.

zoom position = 22X256/(XX+1)

XX; echo back data

If echo back data is “FF”, then following
commands should be sent.

:rF7200000

Echo back data shows zoom position.
[Please refer to the attached Table.1.]

Table.1   Zoom position data table (reference value)

Zoom position

X1

X2

X3

X4

X5

X6

X7

X8

X9

X10

X11

14BA

2DDD

3A56

422D

47C7

4C15

4F96

528E

5517

575B

5953

Echoback data

or less

or less

or less

or less

or less

or less

or less

or less

or less

or less

or less

Zoom position

X12

X13

X14

X15

X16

X17

X18

X19

X20

X21

X22

5B20

5CB1

5E18

5F4B

605D

6143

6208

62AA

6333

63A2

63A2

Echoback data

or less

or less

or less

or less

or less

or less

or less

or less

or less

or less

or more

h) Switch the continuous digi. zoom ON/OFF

:RFCCB00
:WFCCBX

1

X

0

X

1

X

0

=00 ; OFF     X

1

X

0

=01 ; ON (default)

Please attached Continuous digi. zoom flow chart.

i) Set the maximum mag. tuning value  in continuous digi. zoom ON mode

:WFDF0X

1

X

0

X

1

X

(hex) = {256-(256/MM)} (dec)

MM; 

 

maximum mag.

[ EX.

mag.1;  MM=1  X

1

X

0

=00

mag.2;  MM=2  X

1

X

0

=80 ; max. (default)

j) Switch the instant digital zoom ON/OFF

:RFF0F00
:WFF0FX

1

X

0

bit 7 of X

1

X

0

 

:  0-OFF(default)   1-ON

k) Set the instant mag. tuning value in instant digi. zoom ON mode

:WFDE6X

1

X

0

X

1

X

(hex) = IMX10(dec)

IM;  instant mag.

(more than 1.0 and 0.1 step)
[ EX.

mag.1;  IM=1.0  X

1

X

0

=0A

mag.2;  IM=2.0  X

1

X

0

=14 ; max. ]

Summary of Contents for Ceiling DocCam

Page 1: ...1 VideoLabs Ceiling DocCamTM Installation Instructions Operator s Guide ...

Page 2: ...of Ceiling DocCam Package 4 1 2 First Time Set Up 4 1 3 Cable Connections 7 1 4 IR Remote Control 9 1 5 RS 232 Remote Control 9 1 6 Care and Cleaning 10 1 7 Operating And Storage Conditions 10 2 0 Troubleshooting 10 3 0 Technical Specifications 11 4 0 Warranty Information 12 5 0 Quick Connect Guide 14 Appendix 1 RS 232C Control Information 15 ...

Page 3: ...s been tested and found to comply with the limits for a class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause interference to...

Page 4: ...to RJ 45 8 25 Foot S Video S VHS Cable 9 12 Volt DC Power Supply Figure 1 If any of the items are missing please contact VideoLabs at 1 800 467 7157 or 763 542 0061 1 2 First Time Set Up of the Ceiling DocCam The Ceiling DocCam is an integrated document object camera designed for use within a suspended ceiling Recommended ceiling heights are between 8 to 11 feet To locate the Ceiling DocCam above ...

Page 5: ...Module Enclosure Bezel front ring 4 Attach the tile support rails with the aluminum positioning clips to support the weight of the camera on the ceiling tile and between the ceiling grid runners Attach the positioning clips as shown to the tile support rail and to the camera module enclosure fin Slide the tile support rail through the clip into position see Figures 3 4 and tighten down firmly Figu...

Page 6: ...tach the white trim ring to the camera module bezel from the front of the tile and tighten gently This will pull the bezel and camera module together and firmly hold the camera in position against the ceiling tile Rotate the camera enclosure module with the positioning indicator pointing toward the monitor or display device This orientation is standard document camera orientation see Figures 6 7 F...

Page 7: ... Camera Module Enclosure MAIN RS 232 Threaded Inserts The MAIN connector carries S video S VHS composite video and power from the rear of the camera module enclosure to the rear of the wall plate with the provided 50 Category 5 plenum rated RJ 45 to RJ 45 cable Figure 9 The RS 232 connector is provided for use with control systems such as Crestron and AMX the RS 232 cable is not provided Figure 9 ...

Page 8: ...eo Jack BNC S Video Jack RJ 45 Jack The composite video jack and the S video jack are outputs and are connected to inputs of devices such as video conferencing systems monitor receivers VCRs LCD and DLP projectors video switchers video capture cards video to USB adapters etc Note The S Video and the composite video connectors on the Ceiling DocCam plate are both always live It is possible to conne...

Page 9: ...commands of the Polycom ViewStation IR Remote and the PictureTel IR Keypad Please see the VideoLabs Price List for model numbers and ordering information 1 5 RS 232 Control The Ceiling DocCam is equipped with a RS 232 control interface on a RJ 45 Jack Figure 13 See Appendix 1 for RS 232 control interface NOTE All ASCII commands require carriage return at the end of each statement Figure 13 RS 232 ...

Page 10: ...on the back of the camera module enclosure and the RJ 45 jack on the back of the wall plate Make sure the provided 12VDC power supply is plugged into a wall outlet and the 12 V DC jack on the wall plate Do not use any other power supply Check the video connections to verify they are tight and fully inserted Check the input on the video device ie monitor VCR video conferencing system verify it s po...

Page 11: ...uto Back Light Compensation Auto Iris Auto Shutter Auto Exposure Focus Auto Focal Range Infinity 1m T 0 01m w Current Consumption 300mA Control IR Remote or RS 232C Operating Temperature 0o C to 40o C Weight 4 lbs 1 81kg Dimensions 4 5 11 43cm Tall 6 5 16 51cm Diameter Ceiling Cut out 3 5 8 89cm in Diameter Trim Ring 5 5 13 97cm in Diameter Ceiling White Wall Plate S Video Composite Power Cables 5...

Page 12: ...med by the customer prior to repair by a VideoLabs technician Repair time for all cameras is a maximum of 2 business days from receiving to outbound shipping VideoLabs will not accept responsibility for shipment after the camera has left our premises VideoLabs Technical Support VideoLabs technicians will determine and discuss with the customer the criteria for repair costs and or replacement Conta...

Page 13: ...mer customer supplied software or interfacing unauthorized modifications or misuse operation outside of the environment specifications for the product or improper site operation and maintenance All statements technical information and recommendations related to VideoLabs products are based on information believed to be reliable Before using this product you must evaluate it and determine if it is ...

Page 14: ...g systems monitor receivers VCRs LCD and DLP projectors video switchers video capture cards video to USB adapters etc Note Both S VIDEO and COMPOSITE outputs are live 4 Put Batteries in the IR Remote Control and turn the camera ON 5 Use the IR Remote Control to zoom in out on the document object positioned under the Ceiling DocCam 12 V DC Power Supply Suspended Ceiling S Video Comp Video Table or ...

Page 15: ...SCII commands require carriage return at the end of each statement The format of the communication data is shown in Fig 1 a 8 bytes format 1st byte 8th byte CM A3 A2 A1 A0 D1 D0 CM Command as follows R Read 1 byte data of µCom RAM or EEPROM W Write 1 byte data of µCom RAM or EEPROM A3 A0 Address data of µCom RAM or EEPROM write in hex 0000 FFFF D1 D0 Data of µCom RAM or EEPROM write in hex 00 FF b...

Page 16: ...e zoom to TELE WFCBB99 Start WFCBBFE Stop e Move zoom to WIDE WFCBB9B Start WFCBBFE Stop f Select the zoom speed of optical zoom RFDFC00 WFDFCX1X0 Super HIGH SPEED 2 4 sec X1X0 Set bit 3 of echo back data to 0 Set bit 2 of echo back data to 1 HIGH SPEED 3 9 sec X1X0 Set bit 3 of echo back data to 0 Set bit 2 of echo back data to 0 NORMAL SPEED 6 3 sec X1X0 Set bit 3 of echo back data to 1 Set bit ...

Page 17: ...X12 X13 X14 X15 X16 X17 X18 X19 X20 X21 X22 5B20 5CB1 5E18 5F4B 605D 6143 6208 62AA 6333 63A2 63A2 Echoback data or less or less or less or less or less or less or less or less or less or less or more h Switch the continuous digi zoom ON OFF RFCCB00 WFCCBX1X0 X1X0 00 OFF X1X0 01 ON default Please attached Continuous digi zoom flow chart i Set the maximum mag tuning value in continuous digi zoom ON...

Page 18: ...ode wFBBCX3X2X1X0 X3X2X1X0 tuning value min H 0080 max H 03FF X3X2X1X0 H 0080 H 00FF H 0180 H 01FF H 0280 H 02FF H 0380 H 03FF p Set the white balance B gain tuning value in manual white balance mode wFBBEX3X2X1X0 X3X2X1X0 tuning value min H 0080 max H 03FF X3X2X1X0 H 0080 H 00FF H 0180 H 01FF H 0280 H 02FF H 0380 H 03FF q Set the auto iris control level tuning value in auto exposure mode i Iris o...

Page 19: ...fault weighting ratio A B C D Ka 1 Kb 1 Kc 1 Kd 1 4 1 6 1 9 1 F 1 5 7 10 16 s Set the luminance weighting data tuning value RAM area wFDA0X3X2X1X0 X3 X2 X1 X0 0 F 16 step X3 K a X2 K b X1 K c X0 K d EEPROM area wE0A0X3X2X1X0 X3 X2 X1 X0 0 F 16 step X3 K a X2 K b X1 K c X0 K d X3X2X1X0 469F default t Switch the back light compensation BLC ON OFF RAM area RFECE0 WFECEX1X0 X1X0 00 OFF X1X0 02 ON u Se...

Page 20: ...ON 1 3 maximum AGC level W1341X3Y3 AGC gain 1 3 maximum AGC level 2 3 maximum AGC level W1342X2Y2 AGC gain 2 3 maximum AGC level maximum AGC level W1343X1Y1 AGC gain maximum AGC level W1344X0Y0 X X 00 FF 256 step darker H 00 center H 7F brighter H FF Note maximum AGC level setting at page 15 item m x Select the manual aperture mode RAM area RFBFF00 WFBFFX1X0 X1X0 Set bit 1 of echo back data to 1 b...

Page 21: ...maximum AGC gain tuning value in AGC ON mode RAM area wFD46X3X2X1X0 WB5B6Y1Y0 WB5BCY1Y0 X3X2X1X0 0000 0500 0 03125dB step Note condition between X3X2X1X0 and Y1Y0 Y1Y0 X3X2X1X0 8 X3X2X1X0 0000 Y1Y0 00 0dB X3X2X1X0 0500 Y1Y0 A0 40dB EEPROM area wE046X3X2X1X0 W1166Y1Y0 W116CY1Y0 X3X2X1X0 0000 0500 0 03125dB step Note condition between X3X2X1X0 and Y1Y0 Y1Y0 X3X2X1X0 8 X3X2X1X0 0000 Y1Y0 00 0dB X3X2X...

Page 22: ...o yes yes yes no no WIDE TELE ZOOM OPERATION ZOOM START ZOOM END ZOOM TELE Send digi zoom wide command WBFBB04 Send zoom to wide command WFCBB9B Get digi zoom RFC91XX XX MAG XX H FF Optical Zoom area yes Digital Zoom area Fig 1 CONTINUOUS DIGITAL ZOOM FLOW CHART no no Send digi zoom stop command WBFBB00 Send digi zoom tele command WBFBB08 Zoom stop yes yes no WIDE TELE ZOOM TELE Digi Zoom on ...

Reviews: