background image

Keypad display

Actions and comments

CODE NAME : 

OK 

or 

YES

ACCESS 1

REGISTERED

You may name the installer code using the Alphanumeric 

Keypad.

If using automatic setting (called installer default list), 

enter the name of the list. 

Warning

 : If the wrong installers list name is used it 

cannot be set later, the system must be defaulted.

Leaving the name blank by pressing 

ESC NO

, it will be 

named ‘ACCESS 1’ by default.

Please wait

ADJUSTING DATE 

AND TIME

DATE (YEAR):

12/ /

To set the year

OK 

or 

YES

DATE (MONTH):

13/01/

To set the month

OK 

or 

YES

You may proceed in the same way for:

Day

Hour

 and 

Minutes.

13/10/14 10:47

ENTRY COMPLETE !

ACCOUNT NUMBER :

CONNECTED TO 

MONITOR. STATION?

OK 

or 

YES

Use the Alphanumeric Keypad to enter in a 4-8 digit 

account number provided by the Central Station.

ACCOUNT NUMBER :

567001

OK 

or 

YES

ESC

NO

www.videofied.com

I N S T A L L A T I O N   M A N U A L

8

2. XV Panel programming 

Summary of Contents for XV 210

Page 1: ...XV 210 GPRS Control Panel I N S T A L L A T I O N M A N U A L www videofied com Doc Ref 230 XV Last modification date June 2014 Firmware version XLP 04 04 05 XXX and later ...

Page 2: ...possibility to increase its Radio and or GPRS performances through the connection of externally wired antennas Technology TheXValarmpanel likeallVideofieddevices usestheS2View patentedtechnology Whichisaninteractive wireless and AES encrypted technology ensuring signal integrity and optimal security The reliability of the signal is guaranteed thanks to the two way radio frequency transmissions wit...

Page 3: ...200 Speakerphone installation 13 4 XV features guide 14 4 1 Get to access level 4 14 4 2 How to Arm Disarm the system 14 4 3 Arming and Siren mode Configuration 15 4 4 Manage badges and access codes 16 4 5 Delete the keypad or any other device 18 4 6 Read the event log 19 4 7 Programmable inputs and outputs 19 4 8 Golden rules 20 5 Transmitted events list 21 6 2G3G error codes 22 7 Technical speci...

Page 4: ...ght direction DONOTinsertorremovetheSIMcardwhilethepanelispowered 1 1 SIM Card Installation Bracketholes Fixthebackcasingonthewallusingthethreemountingholesasshown Mountingthepanelisnotrequiredforprogramming 1 2 Panel mounting www videofied com I N S T A L L A T I O N M A N U A L 4 1 XV Panel setup ...

Page 5: ...ressandholdthePROGRAMMINGBUTTONfor10seconds untiltheindicatorLEDblinkstwice Thepanelisnowreset aCMA XMAorXMBhastobeenrolledtoconfigurethepanel Mainspowersupply Programmingbutton Option 1 Option 2 THE CONTROL PANEL MUST BE CONNECTED TO AN EXTERNAL POWER SUPPLY OPTION 1 WHEN USING THE RINGTONE FEATURE OR SMARTPHONE APP www videofied com I N S T A L L A T I O N M A N U A L 5 1 XV Panel setup ...

Page 6: ...XX or Press on both CLR and ESC NO keys at the same time and release The indicator LED on the keypad will blink rapidly Wait for the keypad to pair If the keypad doesn t pair up with the panel and shows XX it certainly means that it is still paired to another system and needs to be reset Take the batteries out and press repeatedly on the keypad tamper switch Then proceed to the above steps www vid...

Page 7: ...he control panel The keypad will display a real time radio range value on a scale of 9 To receive the most accurate results you must run the radio range test for at least 30 seconds Result must be 8 out of 9 or better for reliable transmission Using the Alphanumeric Keypad enter the Installer Code of your choice The Installer Code will be used for all future maintenance and configuration This code...

Page 8: ...ame blank by pressing ESC NO it will be named ACCESS 1 by default Please wait ADJUSTING DATE AND TIME DATE YEAR 12 To set the year OK orYES DATE MONTH 13 01 To set the month OK orYES You may proceed in the same way for Day Hour and Minutes 13 10 14 10 47 ENTRY COMPLETE ACCOUNT NUMBER CONNECTED TO MONITOR STATION OK orYES Use the Alphanumeric Keypad to enter in a 4 8 digit account number provided b...

Page 9: ...DIFICATION Keypad display Actions and comments The CODE STATE MODIF menu is to configure the transmitted events to the monitoring station use the arrow keys to toggle between events and OK or YES to modify ALARM event transmitted upon occurrence ALARM END event is transmitted on occurrence and on event restoral NOT TRANSMITTED event is not transmitted however it will appear on the keypad Please li...

Page 10: ...mote maintenance server OK orYES ESC NO ESC NO OK orYES APN CODE internet entrepr USER NAME orange PASSWORD orange The APN Code Access Point Name User Name and Password are supplied by the mobile operator Please make sure you have entered the code exactly as indicated by your local SIM card operator Press OK orYES to enter modify the parameter then OK orYESfor validation Note When entering your SI...

Page 11: ...press any key to light it up except OK orYES ESC NOou CLR The 2G3G level test can last several minutes Do not interrupt the test or remove the SIM card during the test IMPORTANT Videofied will require a 3 5 grade or better for reliable transmission of Video alarms For full compatibility with EN50131 press OK orYES Otherwise press ESC NO Press ESC NO to default the area names Enter the name of the ...

Page 12: ...nnot be armed or disarmed until a user code or badge is entered the installer code cannot arm or disarm the system Press OK or YES to register one or more badges ESC NO if you re not using any badges If you wish to use an user code please skip this step and once the system configuration done go to the BADGES ACCESS CODES menu please refer to chapter 4 4 for further details Badges and codes are lim...

Page 13: ...200 is 30 meters far from the panel the maximum length of the second cable for 2nd TP200 will be10 meters In case of acoustics problems The TP200 module has to be fixed to the wall to eliminate vibrations The TP200 module has to be fixed minimum 1 meter away from the panel In order to avoid interferences with the panel GPRS GSM module To improve the quality of the two way voice communication movin...

Page 14: ...ly Press enter your user code and press OK orYES Press enter your user code and press OK orYES With remote badge reader BR250 N A Present your badge on the badge reader N A N A With remote keyfob N A N A Press Press 4 1 Get to Access level 4 Tue 29 10 11 23 DISARMED LVL 1 ACCESS LEVEL 1 ACCESS LEVEL LEVEL 1 ACCESS LEVEL LEVEL 4 OK orYES OK orYES To unlock and get access to the installer level 4 yo...

Page 15: ...the menu CONFIGURATION LVL 4 AREAS AND DEVICES DEVICES DEVICES CONFIGURATION DEVICE TYPE Siren Immediate triggering of all sirens Delay Beeps Entry Exit delay beeps then triggering of all sirens Silent No Sirens No Beeps Without Siren Beeps on the keypad only Use the to go to menu CONFIGURATION LEVEL 4 SPECIAL ARMING MODES FULL ARM SP1 or SP2 use direction arrows to select the arming mode you want...

Page 16: ...is level User Level 3 can create Level 2 or Level 3 access codes or badges LVL 4 INSTALLER level where it is possible to modify the setup of the panel To access Level 4 the approval of a Level 3 oe Level 2 user is required Installer Level 4 can creat the first Level 3 access code only How to return to the LVL1 After 1 min of no use of the keypad and no tests running the display returns to the stan...

Page 17: ...resent a badge in front of the reader until you hear the registration beep OK orYES OK orYES OK orYES OK orYES OK orYES OK orYES The XV system can accept up to 19 1 installer code Badges or Access codes in any combination The table presents the reserved code possibilities that cannot be used A total of 186 codes are forbidden Reserved Codes Reserved Codes 000000 From 9998 to 9999 From 99998 to 999...

Page 18: ...GURATION GENERAL PARAMETERS OK orYES to select the device and press OK orYES XX DELETE AREAS AND DEVICES DEVICES ADD A NEW DEVICE DEVICE CONFIGURATION A1 KEYPAD KEYPAD 1 OK orYES OK orYES OK orYES Devices list OK orYES OK orYES www videofied com I N S T A L L A T I O N M A N U A L 18 4 XV features guide ...

Page 19: ...n 1 5mA 9V and 3mA 15V If a dry contact is used to trigger the programmable inputs the REF output can be used to supply this dry contact PROGRAMMABLE OUTPUT 1 can be triggered either by a panel event by a peripheral device or by an external event such as a programmable input or a arming input The XV control panel also offer a mapping feature Mapping option allows the input to generate a video clip...

Page 20: ...osedevicesneedstotoprotectanaccessandnotazone 8 Do not fix the keypad at the beginning of the installation as it will need to be portable during programming Always clean the lens of the cameras after the installation Use a clean dry cloth taking care not to exert pressure on the lens 9 10 To switch between UPPER and lower case use the M m key from the CMA keypad or hold a digit key 0 to 9 for XMA ...

Page 21: ... STATE MODIFICATION Use the arrows to access CONFIGURATION level4 CONFIGURATIONMONITOR STATION MONITORINGPARAMETERS EVENTTRANS MODIFICATION Then use the arrows to determine the event to modify Press OK orYES to edit These are the default transmitted events DEVICE intrusions ALERT Panic Buttons PANEL LOW BATT TAMPER DEVICE LOW BATT PERIODIC TEST DURESS CODE FIRE MEDICAL ASSIST ETHERNET CABLE AC POW...

Page 22: ...ents or codes are subject to change by SIM card operators However the GPRS level test errors results in the majority of cases have the following causes SIM Card activation Delay Some operators require an additional delay up to 48 hours to activate automatic data transmission Please check with your operator prior to installation APN CODE USERNAME and PASSWORD The GPRS 2G3G settings are supplied by ...

Page 23: ...tel IP Stack TCP IP Video transmission By Frontel protocol to central monitoring station GPRS antenna Integrated External GPRS antenna Yes via MMCX connector Video Video format MPEG Video size Depending on camera type Video length 10 seconds Miscellaneous Programming With remote Keypad Remote Devices per system 25 maximum Access Badges codes 20 maximum Special arming mode 4 Number of Areas 4 Histo...

Reviews: