2.1
Master system with external 12 V
DC
The master panel
supplies 12 V
DC
. The
wiring scheme is as
follow :
2.2
Master system with dry contact
The master system
opens or closes a
dry contact to
command the XT
arming/disarming.
The wiring scheme is
as follow :
2. Arming and disarming from 9-12V DC
XT Panel
Pr
og
. O
ut
. C
om.
PWR A
C2/DC-
A
rming I
nput 2
Ref +
Pr
og I
nput 3
Ref GND
Pr
og
. O
utput 1
Pr
og
. O
utput 2
Pr
og I
nput 1
Pr
og I
nput 2
Ref GND
A
rming I
nput 1
Ref +
PWR A
C1/DC+
L
N
AC
DC
+
-
Master System with
12 V DC Contact
+
220V AC
XT Panel
Pr
og
. O
ut
. C
om.
PWR A
C2/DC-
A
rming I
nput 2
Ref +
Pr
og I
nput 3
Ref GND
Pr
og
. O
utput 1
Pr
og
. O
utput 2
Pr
og I
nput 1
Pr
og I
nput 2
Ref GND
A
rming I
nput 1
Ref +
PWR A
C1/DC+
L
N
AC
DC
+
-
Master System with
dry contact
220V AC
Arming Inputs :
In XTENDER mode, the system devices are divided into two partitions. Those partitions are controlled either by
Arming Input 1 or Arming Input 2.
When a voltage is applied to Arming Input 1, only the devices in areas 1 & 2 are armed
When a voltage is applied to Arming Input 2, only the devices in areas 3 & 4 are armed
www.videofied.com
4
A P P L I C A T I O N N O T E
www.videofied.com
4
2. Arming and disarming from 9-12 V
DC